COLD WEATHER OPERATION 

Under  humid  conditions  where  temperatures  drop  to  40°F  (4°C)  the  carburetor  and/or  crankcase 
breather system may begin to freeze. To prevent icing take the following steps: 
1.

 

Replace any old fuel with clean, fresh fuel. 

2.

 

Use synthetic 5W-30 or SAE 5W-30 engine oil. Check oil daily or after every 8 hours of use. 

3.

 

Turn fuel valve to the open position. 

4.

 

Ensure generator is serviced according to the maintenance schedule under “Maintenance” section 
of manual. 

5.

 

Shelter unit from elements. 

14

 

TO BALANCE THE LOAD 

To obtain the best output and performance of your Ford Generator it is best to make every effort to 
balance  the  load  on  the  outlets.  Attempt  to  spread  the  load  as  evenly  as  possible  by  utilizing  all 
outlets and try to run higher wattage device on separate outlets when possible. For example; if you 
have a device that draws 2,500W and a device that draws 2,000W, put one plug in the left duplex 
receptacle  and  then  plug  the  other  device  in  the  right  duplex  receptacle  which  would  be  a  more 
balance than placing both plugs in a single duplex receptacle putting 4,500W on one receptacle. 

15

 

CREATING A TEMPORARY COLD WEATHER SHELTER 

In  an  emergency,  the  original  shipping  carton  can  be  used  as  a  temporary  shelter.  The  shelter 
should hold enough heat created by the generator to prevent icing. 
1.

 

Cut off all flaps. 

2.

 

Cut off one of the long sides of the carton to expose the units muffler and exhaust. Do not 
enclose the muffler / exhaust 

3.

 

side of the generator. 

4.

 

Slide carton over generator.  If necessary, remove the wheel assembly for fit. 

5.

 

Maintain 5 feet of clearance between the open side of box and other objects. The exposed side of 
the box should face away from the wind and elements. 

6.

 

Remove shelter when temperatures reach 40°F (4°C). 

 
Regular  maintenance  will  extend  the  life  of  this  generator  and  improve  its  performance.  The 
warranty  does  not  cover  items  that  result  from  operator  negligence,  misuse,  or  abuse.  To  receive 
full  value  from  the  warranty,  operator  must  maintain  the  generator  as  instructed  in  this  manual, 
including proper storage. 

WARNING!  Before  inspecting  or  servicing  this  machine,  make  sure  the  engine  is 
off  and  no  parts  are  moving.  Disconnect  the  spark  plug  wire  and  move  it  away 
from the spark plug. 

16

 

PRE-OPERATION STEPS 

Before starting the engine, perform the following pre-operation steps: 

 

Check the level of the engine oil and the fuel tank level. 

 

Make sure the air filter is clean. 

 

Remove any debris that has collected on the generator and around  the muffler and controls. Use 
a vacuum cleaner to pick up loose debris. If dirt is caked on, use a soft bristle brush. 

 

Inspect the work area for hazards. 

17

 

AFTER EACH USE 

Follow the following procedure after each use: 

 

Shut off engine. 

 

Charge electric starter. (see Battery Charger for Electric Starter pg  15) 

 

Store unit in a clean and dry area. 

Summary of Contents for FG6250P

Page 1: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 1 www fordpowerequipment co uk Fig A1...

Page 2: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 2 www fordpowerequipment co uk Fig A2...

Page 3: ...s Fig 5 13 6 6 Recoil starting Fig 6 FG6250P FG7750P FG9250P 13 7 BEFORE STARTING 14 7 1 Adding Checking Engine Oil See Fig 7 15 7 2 Adding Fuel See Fig 8 15 7 3 Connecting Generator to an Electrical...

Page 4: ...RK ARRESTOR SEE FIG 22 23 24 COOLING SYSTEM 23 25 CARBURETOR ADJUSTMENT 23 26 REPLACING FUEL FILTER SEE FIG 23 24 27 DRAINING FUEL TANK AND CARBURETOR 24 27 1 Draining the fuel tank 24 27 2 Draining t...

Page 5: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 5 www fordpowerequipment co uk 35 2 Maintenance Fout Bladwijzer niet gedefinieerd 36 SERVICE 30...

Page 6: ...hting or serve as a back up power source during power outages It is not designed for professional use WARNING Please read and understand this operating manual before use and keep it for your future re...

Page 7: ...t Guide 1 Spark Plug Wrench 1 Toolkit Phillips screwdriver 1 Combination Wrench 2 Funnel 1 Handles 2 Bushings Flanged 4 Outlets 3 Description Qty M8 x 50mm Hex Bolts for Handle 2 M8 Flanged Nuts for H...

Page 8: ...pen Install a battery operated carbon monoxide alarm near bedrooms Keep exhaust from this unit from entering a confined area through windows doors vents or other openings When working in areas where v...

Page 9: ...ank is empty with the fuel shut off valve turned to the off position WARNING Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid rec...

Page 10: ...t rated frequency and voltage WARNING Only use this unit as intended or serious injury or death could result Do not bypass any safety device Moving parts are covered with guards Make sure all protecti...

Page 11: ...es 2 hair pins 2 washers 2 hub caps and 2 self tapping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the f...

Page 12: ...through the eyelet and tighten the screw and make sure the terminal will not touch any part of the frame Install the Red protection boot Fig 4 Repeat these steps for the Black Terminal WARNING Be car...

Page 13: ...6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 13 www fordpowerequipment co uk 6 5 Installing the handles Fig 5 Fig 5 6 6 Recoil starting Fig 6 Attach the Recoil Starter Grip to the bracket Fig...

Page 14: ...Wear Eye Protection Never Reverse Pole Connections Never turn the battery upside down DO NOT Smoke near the battery If electrolyte contacts the skin wash the area immediately with clean water If you...

Page 15: ...vide space for fuel expansion Fig 8 CAUTION You must add oil before first operating this generator Always check oil level before each operation DO NOT USE E15 OR E85 FUEL IN THIS UNIT IT IS A VIOLATIO...

Page 16: ...s Fig 9 WARNING Generator must be properly grounded to prevent electrocution Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground...

Page 17: ...Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid recoil pull starter cord slowly until resistance is felt then pull rapidly fig 1...

Page 18: ...enerator must be carried fold handle to the down position Never lift or carry generator by its handle CAUTION This product is heavy and requires several people to lift Lift and lower with your legs by...

Page 19: ...oltage V displays the operating voltage of the generator Frequency F displays the frequency in hertz at which the generator is running The Run Maintenance Timer displays the time in hours and minutes...

Page 20: ...heat created by the generator to prevent icing 1 Cut off all flaps 2 Cut off one of the long sides of the carton to expose the units muffler and exhaust Do not enclose the muffler exhaust 3 side of t...

Page 21: ...lent Service Fuel Valve Inspect Muffler and Spark Arrester Check and Clean Air Cleaner Replace Air Filter Clean Cooling System 19CHANGING OIL SEE FIG 19 Run the Generator until the Engine is warm Plac...

Page 22: ...ity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Note Below 40 F 4 C the use of SAE 30 will result in hard starting Above 80 F 27 C the use of 1...

Page 23: ...nd slowly adjust to 0 700 mm 0 800 mm 028 031 if necessary Reinstall spark plug and tighten to Torque 22 0 26 9 Nm 16 20 ft lb Reconnect spark plug wire If spark plug is worn replace only with an equi...

Page 24: ...ior to fill up Fig 22 Fig 23 27DRAINING FUEL TANK AND CARBURETOR To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing the unit for long periods of...

Page 25: ...ris if obstructed For short term storage start generator once every 7 days For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system an...

Page 26: ...500W 6500W 7500W Voltage 110V 230 240V AC Engine 420cc OHV 4 Stroke Air Cooled Engine Oil 10W30 1L Fuel Tank 25L Unleaded Gasoline 31NOISE Noise values measured according to relevant standard K 3 FG62...

Page 27: ...cted from spark plug 6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compre...