Ford FD6700S Operator'S Manual Download Page 26

26

WARRANTY

Ford Power Equipment Limited 1 Year Warranty:

From the date of original purchase, Ford Power Equipment warrants to the original purchaser that each portable 
generator  sold ,  shall be free from defect in material and workmanship for the items and time period set forth 
below. Ford Power Equipment, at its discretion, agrees to repair or replace any defective part that upon examination, 
inspection, and testing by a Ford Power Equipment authorized service dealer, is found to be defective within the 
original warranty period. Ford Power Equipment will also decide upon the use of new or rebuilt parts or comparable 
product. Any part or product that is replaced will be retained by Ford Power Equipment. This warranty period shall 
not be extended and any repaired product shall be warranted for the remaining period of the original warranty. The 
consumer is responsible, and shall prepay all transportation costs, including returning items to the factory or 
warehouse. This warranty is non-transferable and proof of purchase must be presented for requesting warranty
service. If a proof-of-purchase receipt is not provided, the product’s shipping date by the manufacturer will be used 
to determine the warranty period.

Length of Warranty:

Personal use applications of this portable generator are warranted for  month or 500 hrs using (Whichever
comes first). Proof of purchase and of

 

maintenance must be provided.

•    6 Month - Limited comprehensive coverage on all generator components and labor.
•    12 Month - Limited coverage on generator engine and alternator components, parts only.

“Personal use” means personal residential household use or recreational use by the retail consumer. “Commercial use”
means all other uses including commercial, construction, or other income producing purposes. Once a generator has been
used for commercial purposes, it shall thereafter be considered as a “commercial use” generator for the purposes of this
warranty. Any portable generator used for commercial use, as rental equipment or for the purpose of primary power in place
of utility, will not be covered under this warranty.

Consumer Responsibilities:

•    Consumer is responsible for carefully reading and following all instructions in the owner’s manual. Any product that is
     damaged due to misuse or abuse will not be covered by this warranty.
•    Consumer is responsible for all transportation costs to an authorized Ford Power Equipment Service Center. Unless
     otherwise requested, ground shipping will be applied for part shipment and customer will pay any additional charges for
     expedited shipments.
•    Consumer is responsible for labor costs associated with warranted repairs twelve (12) months after the purchase date.
      Labor rates will only be based on normal working hours.
•    
      maintenance may be required to cover warranty requests.
•    Consumer is responsible for presenting any problems with the generator to an authorized Ford Power Equipment
     Service Center as soon as the problem exists. Warranted repairs will be completed in a reasonable period of time, not
     to exceed 30 days.

Consumer is responsible for maintaining generator as specified in the owner’s manual. Documentation of this

Summary of Contents for FD6700S

Page 1: ...MODEL FD6700S www fordpower cc Diesel Generator OPERATOR S MANUAL FD7200S FD7200S T FD6700S T...

Page 2: ...System 13 Operation 13 How to Start Engine 14 Battery Charger for Electric Starter 14 Grounding the Generator 13 How to Stop Engine 15 Receptacles and Extension Cords 15 Don t Overload Generator 16 Wa...

Page 3: ...order parts receive warranty assistance or other services inquiries you can contact us by internet at www fordpower cc Record the following information bellow for service or warranty assistance PULSA...

Page 4: ...r alone Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting Never use indoo...

Page 5: ...unit should be turned off for at least 2 minutes to cool before removing fuel cap If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so...

Page 6: ...eed Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source Generator must be properly grounded to prevent electrocution WARNI...

Page 7: ...ng Stud F Meter Frequency Current Battery Voltage C Socket CEE 3P N T FEATURES A B C D E F Three Phase Single Phase A G H E D I D Outlets H Socket CEE 2P T G Main Circuit Breaker I Circuit Breaker Tim...

Page 8: ...Cover Plate V Maintenance Door S Oil Plug M Fuel Tank Q Air Filter W Battery P Pressure Support Bar R Mechanical Switch Engine T Oil Drain Plug U Maintenance Door Lock X Wheels Y Muffler FEATURES O P...

Page 9: ...acking List Check all loose parts to the following list Contact your dealer if any loose parts are not included 8 10 10 12 Description Qty Generator 1 Quick Start Guide 1 4 Cycle engine oil SAE10W 40...

Page 10: ...touch any part of the frame Repeat these steps for the Black Terminal Attaching Battery Cable See Fig 3 Open Top Cover Plate See Fig 2 Play open the lock See Fig 2A Open the top cover plate upwards Se...

Page 11: ...ON SHIELD EYES EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY NO SPARKS FLAMES SMOKING SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS FLUSH EYES IMMEDIATLEY WITH WATER GET MEDICAL HELP FAST WARNING...

Page 12: ...a level surface wipe dipstick clean then reinsert dipstick without rethreading Adding Checking Engine Oil See Fig 4 You must add engine oil before first operating this generator Always checkengine oi...

Page 13: ...ution The ground terminal located on the back of the generator frame must always be used to connect generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AW...

Page 14: ...r Keep the generator battery fully charged and ready to use in order to avoid generating unit can t start W W WARNING Turn the START ON OFF switch Key to the START position to attempt to start the Eng...

Page 15: ...11 OPER A TION Receptacles and Extension Cords Only use high quality well insulated grounded extension cords in good condition with generator receptacles Follow each load manufacturer s power rating...

Page 16: ...atts to the total Rated Watts in step 1 Keep total load within generator s power capacity Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging th...

Page 17: ...onnected electrical devices Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator 17 Power Management Start engine without anything con...

Page 18: ...ns where temperatures drop to 40 F 4 C Diesel and crankcase ventilation pipe lines may appear to freeze In order to prevent Diesel and crankcase ventilation pipe lines may appear to freeze To prevent...

Page 19: ...ule 19 Engine Oil Air Filter Fuel Filter Oil Filter Fuel Tank Check Level Replace Check Clean Replace Replace Clean Verify Gas Level Each Use O O O Every Month or Each 20 Hrs Every 3 Month or Each 50...

Page 20: ...temperature range expected see Fig 14 Fig 14 W W CAUTION Used oil should be disposed of at an approved disposal site See your local oil retailer for more information 50 122 10W 40 SAE40 Fuel Recommend...

Page 21: ...install air filter so that it seals and replace air filter cover 21 Cooling System Cooling system should only be serviced by an authorized dealer Fuel pump and fuel injector system should only be serv...

Page 22: ...in the fuel system drain the fuel from the tank and carburetor before storing the unit for long periods of time This will help prevent starting problems in the future If the unit is stored with fuel a...

Page 23: ...ove any debris if obstructed For short term storage Less than 1 month No storage procedure required storage 1 to 3 month Fill with fresh diesel fuel storage more than 3 month Draining the fuel tank Re...

Page 24: ...l crankcase to proper oil level place generator on a level surface 8 Low oil level 9 Rich fuel mixture 9 Contact service department 10 Loss of engine compression 10 Contact service department 11 Dead...

Page 25: ...DIAGRAMS 25...

Page 26: ...onents and labor 12 Month Limited coverage on generator engine and alternator components parts only Personal use means personal residential household use or recreational use by the retail consumer Com...

Page 27: ...inal purchaser Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under this warranty Product...