Before
starting
the
engine
,
perform
the
following
pre
-
operation
steps
:
•
Check the level of the engine oil and the fuel tank level.
•
Make
sure
the
air
filter
is
clean
.
•
Remove
any
debris
that
has
collected
on
the
generator
and
around
the
muffler
and
controls
.
Use
a
vacuum
cleaner
to
pick
up
loose
debris
.
If
dirt
is
caked
on
,
use
a
soft
bristle
brush
.
•
Inspect the work area for hazards.
Pre-Operation Steps
After Each Use
Follow
the
f
ollowing
p
rocedure
a
fter
e
ach
u
se
:
•
Shut off engine.
•
Charge electric starter. (see Battery Charger for Electric Starter pg 14)
•
Store unit in a clean and dry area.
Maintenance Schedule
19
Engine Oil
Air Filter
Fuel Filter
Oil Filter
Fuel Tank
Check Level
Replace
Check
Clean
Replace
Replace
Clean
Verify Gas Level
Each Use
O
O
O
Every Month or
Each 20 Hrs
Every 3 Month or
Each 50 Hrs
Every 6 Month or
Each 100 Hrs
Every 12 Month or
Each 300 Hrs
O(First Use)
O
O
O
O
O
Changing Oil (See Fig 13)
• Run the Generator until the Engine is warm.
• Place generator on a level surface.
• Remove the crankcase dipstick.
• Place an oil pan underneath the oil drainage bolt to collect used oil.
• Remove the oil drainage plug and allow oil to drain completely.
• Reinstall oil drainage plug, tighten securely.
• Carefully add SAE 10W-40 CD to empty reservoir until the oil reaches
the outer edge of the oil fill hole (Crankcase Dipstick hole).
• Replace crankcase dipstick.
Fig 13
Oil Fill & Dipstick
Oil drainage plug