SET UP

  

1.FILL / ADD VAPOR PRODUCING FLUID 

a. Remove fluid fill plug with hex key.

b. Pour OEM-Approved Vapor Producing Fluid into fluid  

    fill port. 

c. Fill fluid fill port until fluid level is near top of port. 

d. Replace fluid fill plug.

               

 

    2 fl. oz. (60 ml) maximum to refill when empty

2. CONNECT TO POWER 

•  Use the power selector switch on rear of machine to 

select input power, AC or DC. 

•  If 12 Volt DC is preferred, connect the battery cables to 

a fully charged 12 Volt battery. RED to positive, BLACK 

to chassis ground. 

•  If AC power is preferred, connect a properly rated 

power cord into the AC Power Port.

•  Green Power Indicator lamp illuminates with proper 

power hook up and power source selected.

!

             

 

Never connect Rotunda PowerSmoke

 to a battery charger or jumper box.  

              

 

Never connect Rotunda PowerSmoke

 to vehicle with engine running. 

 

3. CONNECT TO AIR SUPPLY 

 

    a. Connect compressed air supply to Air Inlet. 

 

        *Replace quick coupler fitting if necessary. 1/4 in. NPT male.

4. Adjust Rotunda PowerSmoke

 for testing

  a.  Turn Flow Control Valve off.

  b. Set desired Test Pressure. (

PULL

 to unlock, 

TURN

 to adjust pressure, 

PUSH

 to lock)

  c. Attach Vapor Hose to installed adaptor of system being tested.

  d. Depress the 

Vapor Test Switch (#5)

 button to begin 10-minute vapor test cycle.

  e. Turn Flow Control Valve to release pressure / vapor.

  f. Use inspection light provided to inspect for leaks.

!

!

Summary of Contents for 95-0182

Page 1: ...OPERATION MANUAL P N 95 0182...

Page 2: ...t up 5 Adaptor Installation 6 Testing for Leaks 7 8 Trouble Shooting 8 Warranty 9 Replacement Parts 9 Technical Support 1 800 55 SMOKE 1 714 451 1411 Email Support info RedlineDetection com You will r...

Page 3: ...0V AC or 12V DC Pressure Supply Compressed Air Output Pressure 2 to 20 PSI 0 14 to 1 4 BAR Operating Temperature 0 F to 140 F 17 C to 60 C Operating Humidity No Restrictions Operating Altitude No Rest...

Page 4: ...ycle Push again to stop testing 6 Air Only Test Switch Begins 10 minute air only cycle Blue light indicates air only cycle Push again to stop testing 7 Reset Switch Clears stored logic 8 Adjustable Pr...

Page 5: ...including debris residue in the Intake Exhaust system coefficient of friction internal pressure of the Power INTAKE Adaptor and the accuracy of inflation instruments Generally a Power INTAKE Adaptor...

Page 6: ...tiniest wisps of vapor under the hood or chassis 8 AC Power Cable 20 0010 Use when selecting AC Power Make sure cable is rated to match input voltage and plug configuration 9 OEM Approved Vapor Produc...

Page 7: ...the AC Power Port Green Power Indicator lamp illuminates with proper power hook up and power source selected Never connect Rotunda PowerSmoke to a battery charger or jumper box Never connect Rotunda...

Page 8: ...nflation pressure with Power INTAKE Adaptor or a test pressure that is greater than the capacity of the weakest component in the system under test NEVER use Power INTAKE Adaptor when its failure could...

Page 9: ...from the air box to the tip of the exhaust completely in a single test To do so install Power INTAKE Adaptor see instructions into intake ducting after air cleaner box AND install Power INTAKE Adaptor...

Page 10: ...erformed to confirm proper repair and seal IMPORTANT NOTE Many leaks in systems are considered normal or within tolerance For example a weep hole in a muffler is acceptable DO NOT assume every wisp of...

Page 11: ...refund of the purchase price This warranty shall void if a product is improperly maintained altered abused or otherwise misused in any way THE AFORESAID WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES AN...

Page 12: ...Manufactured By Redline Detection LLC Technical Support 1 714 451 1411 Email info redlinedetection com P N 01 0111 B...

Reviews: