Ford 95-0182 Operation Manual Download Page 4

2

REFERENCE GUIDE

FRONT VIEW

BACK VIEW

6

5

4

7

8

9

2

3

1

12

10

11

15

14

16

13

1. Flow Control Knob (Variable)

Releases vapor / pressure into the system

Close flow control valve to lock out system for pressure 
decay testing

2. System Pressure Gauge

Displays the back pressure of system under test

3. Flow Meter

Measures flow rate into system under test

4. Power Indicator

Green light indicates proper connection to 
electrical power

 

5. Vapor Test Switch

Begins 10-minute vapor cycle. Red light indicates vapor 
cycle. Push again to stop testing

6. Air Only Test Switch

Begins 10-minute air only cycle. Blue light indicates air 
only cycle. Push again to stop testing  

7. Reset Switch

Clears stored logic

8. Adjustable Pressure Regulator 

Adjust test pressure from 2 to 20+ PSI (0.14 to 1.4+ BAR)

9. Test Pressure Gauge

Indicates test pressure set by regulator

10. Fluid Fill Port

Remove fluid fill plug to fill machine with OEM- 
Approved Vapor Producing Fluid

11. Vapor Output Hose

12. Compressed Air Inlet

Replace coupler fitting if necessary. Female 1/4 in.  
NPT fitting

13. 12 Volt DC Power Cables

14. International AC Power Inlet (110-240V)

15. Power Supply Selector Switch

AC-OFF-DC

16. Fuse Holder

2.5A 250V Fuse plus one spare fuse

Summary of Contents for 95-0182

Page 1: ...OPERATION MANUAL P N 95 0182...

Page 2: ...t up 5 Adaptor Installation 6 Testing for Leaks 7 8 Trouble Shooting 8 Warranty 9 Replacement Parts 9 Technical Support 1 800 55 SMOKE 1 714 451 1411 Email Support info RedlineDetection com You will r...

Page 3: ...0V AC or 12V DC Pressure Supply Compressed Air Output Pressure 2 to 20 PSI 0 14 to 1 4 BAR Operating Temperature 0 F to 140 F 17 C to 60 C Operating Humidity No Restrictions Operating Altitude No Rest...

Page 4: ...ycle Push again to stop testing 6 Air Only Test Switch Begins 10 minute air only cycle Blue light indicates air only cycle Push again to stop testing 7 Reset Switch Clears stored logic 8 Adjustable Pr...

Page 5: ...including debris residue in the Intake Exhaust system coefficient of friction internal pressure of the Power INTAKE Adaptor and the accuracy of inflation instruments Generally a Power INTAKE Adaptor...

Page 6: ...tiniest wisps of vapor under the hood or chassis 8 AC Power Cable 20 0010 Use when selecting AC Power Make sure cable is rated to match input voltage and plug configuration 9 OEM Approved Vapor Produc...

Page 7: ...the AC Power Port Green Power Indicator lamp illuminates with proper power hook up and power source selected Never connect Rotunda PowerSmoke to a battery charger or jumper box Never connect Rotunda...

Page 8: ...nflation pressure with Power INTAKE Adaptor or a test pressure that is greater than the capacity of the weakest component in the system under test NEVER use Power INTAKE Adaptor when its failure could...

Page 9: ...from the air box to the tip of the exhaust completely in a single test To do so install Power INTAKE Adaptor see instructions into intake ducting after air cleaner box AND install Power INTAKE Adaptor...

Page 10: ...erformed to confirm proper repair and seal IMPORTANT NOTE Many leaks in systems are considered normal or within tolerance For example a weep hole in a muffler is acceptable DO NOT assume every wisp of...

Page 11: ...refund of the purchase price This warranty shall void if a product is improperly maintained altered abused or otherwise misused in any way THE AFORESAID WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES AN...

Page 12: ...Manufactured By Redline Detection LLC Technical Support 1 714 451 1411 Email info redlinedetection com P N 01 0111 B...

Reviews: