Installation, Operating & Service Manual
IMPORTANT
IF, DURING NORMAL OPERATION, IT IS
NECESSARY TO ADD MORE WATER THAN
INDICATED BELOW, CONSULT A QUALIFIED
SERVICE TECHNICIAN TO CHECK YOUR SYSTEM
FOR LEAKS .
Boiler Model
Gallons Per
Month
Gallons Per
Year
FORCEOL084-E
0 .20
2
FORCEOL115-E
0 .20
2
FORCEOL140-E
0 .25
3
FORCEOL182-E
0 .30
4
C .
ATTENTION TO BOILER WHILE NOT IN
OPERATION
NOTICE:
If boiler is not used during winter time, it
must be fully drained to prevent freeze damage.
1. Prevent Freeze Damage
Important:
If boiler is
NOT
used during winter
time, it must be fully drained to prevent freeze
damage.
2. Spray inside surfaces with light lubricating or
crankcase oil using gun with extended stem so
as to reach all corners.
3. Always keep the manual fuel supply valve shut
off if the burner is shut down for an extended
period of time.
4. To recondition the heating system in the fall
season after a prolonged shut down, follow the
instructions outlined in Section X, System Start-
Up, Paragraphs A through K.
WARNING
This boiler contains controls which may cause
the boiler to shut down and not restart without
service. If damage due to frozen pipes is a
possibility, the heating system should not be
left unattended in cold weather; or appropriate
safeguards and alarms should be installed on
the heating system to prevent damage if the
boiler is inoperative.
12
Service and Maintenance Instructions
(continued)
!