G.) Repeat above steps “A ~ F” for each of the grease zerks on the
Valve body.
H.) Once lubrication is complete, the valve should be cycled 2-3 times and checked to
see if sealing has been restored.
* Note: the use of g/s to repair a leaking valve should be carefully considered by the
owner/operator of the piping system. g/s may not be a viable long-term alternative to
valve repair in some circumstances depending on how critical the service requirement may
be. For valves where bubble tight sealing is important to prevent injuries, death,
environmental hazards, or costly damage, etc. g/s should only be used as a temporary
solution, and the valve should be promptly repaired by a qualified valve repair specialist.
The lubricant / sealant must be displaced before the heavier sealant fills the sealant system.
The same calculations used for injecting valve cleaner are applicable (one (1 oz.) ounce per
inch of valve size into each seat ring plus riser pipe quantities).
2.4.6. Recommended spare parts for repair.
- Table A (Recommended Spare parts for Repair) -
Part No
Parts
Q’ty
Part No
Parts
Q’ty
8
GLAND
PACKING
1
45A
O-RING
1
19A
GASKET
1
45B
O-RING
1
19B
GASKET
1
45C
O-RING
1
19C
GASKET
1
45D
O-RING
2
150
SEAT
RETAINER
1set
45E
O-RING
2
151
RETAINER
RING
1set
45F
O-RING
1
* Note: See the Chapter
Ⅶ
. Disassembly and Reassembly Section 3. Cross-sectional
assembly drawing.
* Note: The table represents only a typical part of the Force Trunnion valve. Should repair
(that is not solved by flushing or sealant injection) become necessary, please obtain the
valve part number and serial number, and contact the CNC Flow Control.
Ⅵ. Perio
dic inspection