14
4. Operation
4-1. Power ON
After verifying that all wiring is correctly connected, apply power to the UFM frame. The
UFM-30DEMUX will start up and display "UFM30DMX" as shown below.
4-2. Operation and Menu Modes
4-2-1. Operation (Normal) Mode
After powering itself on, the UFM-30DEMUX will enter
Operation
mode and display the SDI
signal status.
If the SDI signal is normal, "
READY
" will be displayed.
If the SDI signal is abnormal, an error message will be displayed. (See the table below.)
R E A D Y
SDI status display
Description
READY
SDI signal is present.
NO SIG
No SDI signal is present.
CRC ERR
A CRC error is detected.
OP ERR
An incompatible option item is
installed.
IMPORTANT
"OP ERR" is displayed when an incompatible option module is connected to the
UFM-30DEMUX. Power off the frame, remove and disconnect the optional module.
To return to Operation mode
To return to
Operation
mode from
Menu
mode, move the
position.
switch to the
Up
PUSH
OPERATE
LOCK
AES
LTC
UFM-30MUX
U F M 3 0 D M X
PUSH
OPERATE
LOCK
AES
LTC
UFM-30DEMUX
Up/Down
USO
RESTRITO