MIN/MAX

~Hz

PEAK

HOLD

Data Acquisition

2

2

#61-492

490 Series

Industrial Grade Multimeter

MIN/MAX

~Hz

PEAK

HOLD

Data Acquisition

2

1. LCD Display
2. Rotary Function Switch
3. COM Input Terminal
4. V

Hz Input Terminal

5. mA Input Terminal
6. A Input Terminal
7. Backlight Button
8. ~Hz Button
9. Peak H Button
10. Range Button
11. Blue Switch Button
12. Min/Max Button
13. REL

Button

14. Hold Button

1

10

14

7

2

3

4

5

6

11

12

13

8

9

Содержание ND 2385-1

Страница 1: ...D Data Acquisition 2 1 LCD Display 2 Rotary Function Switch 3 COM Input Terminal 4 V Hz Input Terminal 5 mA Input Terminal 6 A Input Terminal 7 Backlight Button 8 Hz Button 9 Peak H Button 10 Range Bu...

Страница 2: ...be performed on cir cuits capable of delivering greater than 500 Volts 2 To avoid electrical shock hazards and or damage to the meter Do not exceed the voltage ratings for the meter Use caution when m...

Страница 3: ...utton This function displays the differential between the actual measurement and the last value displayed before pressing the REL button Pressing the hold button while in this function stops the displ...

Страница 4: ...M over 1000M in 400mV range MIN MAX Hz PEAK HOLD Data Acquisition 2 Circuit Connection 7 AC Volts Range Resolution Max Display Accuracy 400mV 0 1mV 400 0 1 5 8 40Hz 60Hz 4V 1mV 4 000 1 0 5 40Hz 500Hz...

Страница 5: ...V IR 100kA fuse for A input 10 MIN MAX Hz PEAK HOLD Data Acquisition 2 Circuit Connection AC Current Range Resolution Max Display Accuracy Voltage Burden 40mA 1 A 40 00 1 0 5 300mV max 400mA 0 1mA 400...

Страница 6: ...pprox MIN MAX Hz PEAK HOLD Data Acquisition 2 Circuit Connection 11 Frequency RPM Range Resolution Max Display Sensitivity Accuracy 4kHz 40kRPM 1Hz 30RPM 4 000 40 00 150mV Frequency 2 0 Hz 0 01 1 1 5V...

Страница 7: ...play Accuracy 4nF 1pF 4 000 3 0 10 40nF 10pF 40 00 3 0 5 400nF 100pF 400 0 4 F 1nF 4 000 40 F 10nF 40 00 400 F 100nF 400 0 4mF 1 F 4 000 5 0 20 40mF 10 F 40 00 In these two ranges the reading may be r...

Страница 8: ...reading 90 of full scale Noise generating fields may affect intervals MIN MAX Hz PEAK HOLD Data Acquisition 2 Continuity Check To Verify Continuity 1 A continuity test ensures that all circuit connec...

Страница 9: ...ng the rotary switch If the meter is Re Powered on by pushing key switch the LCD displays the saved state when meter auto power off itself pushing Hold key switch to disable the hold state The meter w...

Страница 10: ...is 1 if battery low condition is true OL indicates input overflow 0 1 1 Judge Sign BATT OL Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 19 Range This packet indicates the full scale range of the meter W...

Страница 11: ...CR Carriage return The transmitted code is 0001101 LF Line Feed The transmitted code is 0001010 C US General Specifications Display The Liquid Crystal Display LCD with a maximum reading of 4000 and 8...

Страница 12: ...state to state IDEAL INDUSTRIES INC Sycamore IL 60178 U S A 800 304 3578 Customer Assistance www testersandmeters com ND 2385 1 Made in Taiwan Maintenance Battery Installation or Replacement The 61 4...