4-3-1. Command Responses 

 

Echo and Prompt 

Responses will be sent as shown below when receiving commands: 

A command is received. 

 

↓ 

 

Echo 

@[sp]X:<Lvls>/<Dest>,<Src>[CR] 

↓ 

 

Prompt 

[CR][LF]> 

MFR units respond with an Echo Reply with the same data that they received. Therefore, echo 
reply messages end with [CR][LF] or [CR] only. If echo messages with [CR][LF] are received, only 
[LF] composes the second line.

 

MFR units read a command, ended with a newline, and return a prompt to notify that they are 
ready to receive a new command.

 

A carriage return and line feed are not added at the end of “Echo Reply” and “Prompt” 

 

 

“C” responses (Command 1-6)

 

A “C” response is sent as shown below when a control command is received: 

 

[CR][LF]C:<Lvls>/<Dest>,<Src>[

[S<

Salvo number

>][L<

Link number

>]]:I<ID>[CR][LF] 

C responses are sent to all the terminals in the system. 

 

Parameter 

Setting range 

Description 

<Salvo number 
>

 

1

-

FFF 

The number of crosspoints that are to be changed 
simultaneously by Salvo settings. 
A response if 3 crosspoints are to be changed 
simultaneously:  

C:0/0,0...S2:IA

 

<Link number>  1

-

FFF 

The number of crosspoints that are to be changed 
simultaneously by Link settings. 
A response if 2 crosspoints are to be changed 
simultaneously:  

C:0/0,2...L1:IA

 

 

 

 

An “S” response is sent as shown below when crosspoints are switched by a command. 

 

[CR][LF]S:<Lvl><Dest>,<Src>[CR][LF] 

*  If a crosspoint is switched by an X or B command, its 

“S” response is sent to all the terminals in the 

system. However, if any crosspoints are not switched (specifying the same crosspoint as the current one), 
its “S” response is sent only to the terminal that sent the command. 

 

*  S responses are sent before C responses in some cases.

 

*  A command is received from another terminal while a B or X command is proce

ssed, MFR units send “S” 

response messages to the terminals, notifying only the latest crosspoint states. 

*  A crosspoint switch command is not performed if the relevant crosspoint is locked or inhibited to change.

  

 

Ex. 1

) When 

Source 5

 is selected for 

Destination 3

 in 

Level 1:

 

(Function 3 in the previous page) 

(A) 

@ X:0/2,4[CR] 
[CR][LF]> 

(B) 

[CR][LF] 
C:0/2,4:IA[CR][LF] 

(C) 

[CR][LF] 
S:02,4[CR][LF] 

 

 
 

@ X:0/2,4 

C:0/2,4:IA 
 
S:02,4 

Terminal display: 

Summary of Contents for MFR-1000

Page 1: ...MFR 1000 Multi Format Routing Switcher 1st Edition Rev 1 OPERATION MANUAL...

Page 2: ...2 Edition Revision History Edit Rev Date Description Section Page 1 2018 10 30 1 1 2019 02 06 Supported GPI IN TALLY OUT Deleted MFR TALM Changed 12G SDI cable equalization length 2 2 1 6 1 1...

Page 3: ...round the unit to gas lines units or fixtures of an explosive or dangerous nature Operation Hazard Do not operate the unit under hazardous or potentially explosive atmospheric conditions Doing so coul...

Page 4: ...d disconnect the power cord to avoid potentially hazardous conditions If problems similar to the above occur contact an authorized service representative before attempting to operate the unit again Ra...

Page 5: ...y the Company After upgrading software User may not use an earlier version without the Company s prior permission 5 Term of Validity of Agreement This agreement shall be effective for a period of one...

Page 6: ...64RUW MFR 8RUA 1 Remote Control Unit Interface Expansion Unit ITEM QTY REMARKS MFR GPI 1 AC Adaptor 1 With DC lock plug AC cable 1 Rack Mount Brackets 1 set EIA standard type LAN Cable straight 1 Dep...

Page 7: ...ol 18 4 1 Serial Interface 18 4 2 LAN Interface 18 4 3 Control Command 19 4 3 1 Command Responses 21 4 3 2 Receiving Responses Commands 1 6 22 4 3 3 Channel Name Request Commands 7 25 4 3 4 CPU Status...

Page 8: ...op Built in webserver for remote control through a web browser SNMP support enabling SNMP monitoring system configuration Status monitoring for power supply fan CPU and etc Power unit redundancy for s...

Page 9: ...O12G MFR 8SDI12G INPUT 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 The figure shown above displays a rear panel with MFR 8SDI12G and MFR 8SDO12G installed No Name Des...

Page 10: ...8 19 20 21 22 6 10 7 8 9 Pin No Description Pin No Description 1 GPI IN1 14 TALLY OUT1 2 GPI IN2 15 TALLY OUT2 3 GPI IN3 16 TALLY OUT3 4 GPI IN4 17 TALLY OUT4 5 GPI IN5 18 TALLY OUT5 6 GPI IN6 19 TALL...

Page 11: ...The following items can be set for ALAM OUT Assign alarms in the Web Based Control Fan Power Crosspoint Error GPI OUT TALLY OUT Circuit The voltage is about 0 9V when turned on MFR 1000 VCC VCC Exter...

Page 12: ...the GPI unit Color indications on the MFR GPI front panel LED LED Color LED Green Red Orange POWER Normal Power alarm BUSY Normal processing Writing to flash memory POWER LED lights red if the unit is...

Page 13: ...I_IN TALLY_OUT 01 20 GPI_IN TALLY_OUT 20 2 GPI_IN TALLY_OUT 02 21 GPI_IN TALLY_OUT 21 3 GPI_IN TALLY_OUT 03 22 GPI_IN TALLY_OUT 22 4 GPI_IN TALLY_OUT 04 23 GPI_IN TALLY_OUT 23 5 GPI_IN TALLY_OUT 05 24...

Page 14: ...OUT TALLY OUT Circuit The voltage is about 0 9V when turned on MFR GPI VCC VCC External device Switch or relay MFR GPI VCC VCC External device Open Collector External device Max voltage 40V MFR GPI M...

Page 15: ...7 RTS Request To Send 8 CTS Clear To Send 9 NC Not used The maximum cable length is 10 m DTR DSR and RTS CTS are internally connected respectively RS 422 Connector Pin Assignments Factory default sett...

Page 16: ...for maintenance Do not use S12 S14 Used to select RS 232C RS 422 for SERIAL 1 The default setting is RS 232C both switches to the left To change to RS 422 set both switches to the right Switch Setting...

Page 17: ...RUA Setup Menu MFR 18RU 18RUA MFR 16RUTA Setup Menu MFR 16RUTA MFR 8RUA Setup Menu MFR 8RUA Other RUs Setup Menu MFR 16 40RU MFR 16RUD MFR 16 32 64RUW RU Settings page MU Settings page MFR 39RUA Setti...

Page 18: ...the MFR 1000 unit is the server Basic specifications Item Description IP address PC LAN port 192 168 1 12 Subnet Mask 255 255 255 0 Port number Setting range 49152 to 65534 Default 23 Number of PCs M...

Page 19: ...n needs to be specified Yes 10 Commands for requesting System Size Yes Yes Crosspoint remote control Crosspoint remote control 2 11 Commands for setting video format reference and or switching point Y...

Page 20: ...icates a space Commands must end with a carriage return ASCII code 0x0D only or carriage return and line feed ASCII code 0x0A MFR units add a carriage return and line feed in front of and at the end o...

Page 21: ...crosspoints are to be changed simultaneously C 0 0 0 S2 IA Link number 1 FFF The number of crosspoints that are to be changed simultaneously by Link settings A response if 2 crosspoints are to be chan...

Page 22: ...commands as well as V and B E commands after executing many preset commands send the next command after having finished receiving all strings of reply messages Ex 1 Allows to send the next command wh...

Page 23: ...Add to the line buffer Processing S Response Does the line buffer begin with S Other characters are recognized and used as tally Characters are cleared if unnecessary Processing C Response Does the l...

Page 24: ...F 2 C CR LF S 130 70 CR LF 2 C CR LF S 230 70 CR LF 2 C CR LF S 330 70 CR LF 2 C CR LF S 430 70 CR LF 2 C CR LF S 530 70 CR LF 2 C CR LF S 630 70 CR LF Message examples returned to Terminal 2 2 A X 12...

Page 25: ...o 1 2 3 4 5 6 7 8 10 11 Command sp K S A 000 0FF CR D K Command response BYTE No 1 2 3 4 5 6 7 9 10 11 Response CR LF K S A 000 0FF CR LF D K Command Response BYTE 5 S or D Select between S Source or...

Page 26: ...K SA 000 Echo K SA000 5352432031 Ascii Name for Source Channel 1 is SRC 1 K SA001 5352432032 Ascii Name for Source Channel 2 is SRC 2 K SA002 5352432033 Ascii Name for Source Channel 3 is SRC 3 I K S...

Page 27: ...Channel 101 is K DK065 E587BAE58A9BEFBC91EFBC90EFBC92 Kanji Name for Destination Channel 102 is K DK066 E587BAE58A9BEFBC91EFBC90EFBC93 Kanji Name for Destination Channel 103 is I K DK083 E587BAE58A9BE...

Page 28: ...Kanji Name for Source Channel 66 is K SK042 E382ABE383A1E383A9EFBC93 Kanji Name for Source Channel 67 is K SK043 E382ABE383A1E383A9EFBC94 Kanji Name for Source Channel 68 is K SK044 Kanji Name for So...

Page 29: ...lows you to indicate if the CPU is active or passive in the MFR 1000 Command format Control command Command response sp A sp A ID Control command BYTE No 1 2 3 4 Command sp A Command response BYTE No...

Page 30: ...l Dest ID 0 CR LF 1 2 Command Response Examples 1 If Destination 1 is locked by ID10 Unit using LOCK ALL Destination 1 status returns as shown below Response W 0 0 Echo W 00 A 1 Dest 1 is locked by ID...

Page 31: ...Command description Commands Command response 1 Sets video format reference and or switching point beforehand sp UF YY R S 1 UF YY R S 2 Performs the set changes sp UE A UR W 2 UR YY R S UR E error re...

Page 32: ...0E 1080 30psF 0F 1080 29 97psF 10 1080 25psF 11 1080 24psF 12 1080 23 98psF 13 NTSC 14 PAL R Reference RA Auto RB B B RT Tri Sync S Switching point SF Field SO Odd SE Even Commands are not executed if...

Page 33: ...ck Remedy No image output Are there signal inputs to the video input connectors Input video signals to the video input connectors Are cables properly connected for the signal inputs Connect cables pro...

Page 34: ...ant with the following standards 75 BNC SMPTE ST 2082 10 12G SDI SMPTE424M 3G SDI SMPTE292M HD SDI SMPTE259M SD SDI Cable Equalization 12G SDI 70m L 5 5CUHD cable 3G HD SDI 100m 5C FB cable SD SDI 200...

Page 35: ...including Mai Remote and GPI units Interface MFR LAN 10 100BASE TX RJ 45 x 1 Ethernet hub is needed for Main and multiple unit connections SERVICE RS 232C 9 pin D sub male x 1 for maintenance GPI IN T...

Page 36: ...1000 CANCEL CONTROL ROUTING SWITCHER POWER 2 POWER 1 ON ON OFF OFF t 2 3 AC100 240V 50 60Hz IN 1 2 MFR 1000 PC LAN MFR LAN REF IN GPI IN TALLY OUT OUTPUT MFR 8SDO12G MFR 8SDI12G INPUT 8 7 6 5 4 3 2 1...

Page 37: ...en the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual ma...

Page 38: ...166 USA Tel 1 305 931 1700 Fax 1 714 894 5399 FOR A Europe S r l Via Volturno 37 20861 Brugherio MB Italy Tel 39 039 91 64 811 Fax 39 039 878 140 FOR A UK Limited Trident Court 1 Oakcroft Road Chessin...

Reviews: