![FOR-A MFR-1000 Operation Manual Download Page 18](http://html1.mh-extra.com/html/for-a/mfr-1000/mfr-1000_operation-manual_2316762018.webp)
18
4. Serial / LAN Command Control
4-1. Serial Interface
Crosspoint switchover and tally output can be controlled via the SERIAL ports 1 to 4 on the MFR
GPI.
4-2. LAN Interface
The MFR-1000 unit is able to connect to a third-party automatic control system via the RJ-45 port
(PC-LAN port). TCP/IP communication protocol is supported. The control PC is the client and the
MFR-1000 unit is the server.
Basic specifications
Item
Description
IP address (PC-LAN port)
192.168.1.12
(Subnet Mask: 255.255.255.0)
Port number
Setting range: 49152 to 65534 (Default: 23)
Number of PCs
Max. 16
Response / Resending
Wait before sending next command (Resend if the Echo is not
returned.)
Login password
None
Communication protocol
TCP/IP
Control PC: Client
MFR-1000: Server
Crosspoint Remote Control using ASCII code.
Command protocol
Crosspoint Remote Control protocol
Hub
Client
No.1
Client
No.2
Client
No.**
MFR-1000
PC-LAN Port
Web-based
Control