13
4. Setup Menu
Network settings such as IP address setting can be changed in the Setup menu. Prepare a PC to
connect to the HVS-GPIO128 via LAN or RS-232C. Use a terminal software (such as Tera Term) to
communicate with HVS-GPIO128.
4-1. If Connecting via LAN
(1) Change the PC IP address to
192.168.0.10
(Netmask:
255.255.255.0
).
(2) Connect the PC and HVS-GPIO128 using LAN.
(3) Launch a terminal software on the PC
(4) Specify
192.168.0.40
(IP address of HVS-GPIO128) to connect to the HVS-GPIO128.
4-2. If Connecting via RS-232C
(1) Use an RS-232C cable to connect the PC to the SERVICE port on the HVS-GPIO128.
(2) RS-232C communication specifications of the HVS-GPIO128 are as shown below.
Set the PC RS-232C communication settings accordingly.
HVS-GPIO128
Serial Communication Specifications
Baud rate
38,400 bps
Data bit
8-bit (fixed)
Parity
None (fixed)
Stop bit
1-bit (fixed)
Flow control None
(3) Open a terminal software on the PC.
(4) Select RS-232C serial communication to connect to the HVS-GPIO128.
2 -DC12V IN- 1
SERVICE
1
2
3
4
GPI 2
GPI 1
GPI 3
GPI 4
RATING LABEL
SERIAL
MFR-LAN
PC
Terminal software