TCP/IP COMMUNICATION PROTOCOL
Connect the matrix to a PC using Cat 5e/6 cable.
The default parameters of the matrix
FO-20M44XT
are as follows:
- IP address:
192.168.0.178
- Subnet mask:
255.255.255.0
- Default gateway:
192.168.0.1
Configure the PC in the same range as the matrix to make the device operate via the TCP/IP communication
protocol. To do so, modify the value of the IP address within the same range as the matrix.
COMMAND
FUNCTION
%9976.
Checks the resolution of the output channels
%9977.
Checks the digital audio status of the output channels
%9978.
Checks if the inputs are compatible with HDCP
I-Lock[x].
Locks the channel [x]
[x] is the channel number (1, 2, 3, 4)
I-Unlock[x].
Unlocks the channel [x]
[x] is the channel number (1, 2, 3, 4)
A-Lock.
Locks all the channels
A-UnLock.
Unlocks all the channels
Lock-Sta.
Checks the lock status of all the channels
- 8 -
EN
FO-20M44XT_MANUAL_(EN_ES_FR_PT)_A5c_20200921-2020.qxp_Maquetación 1 21/9/20 11:19 Página 8