________________________________________________________________________________
45
AST 14 C 259/00
* the first vent elbow from the boiler is not to be accounted for
Basic split kit 0SDOPPIA11:
WARNING: air diaphragm is supplied with the split kit.
80/80 split duct load loss table
Part Vent
Intake
1 m extension
1
0.6
0.5 m extension
0.5
0.3
90° elbow
1.3
0.8
Narrow radius 90° elbow
2.7
1.6
45° elbow
2.3
1.3
Elbow with flue pressure measurement
point
2.7 1.6
Wall vent terminal
4.3
-
Roof vent terminal
4.3
-
Vertical stub pipe
0.1
0.1
Vertical condensate vent
2.7
-
Horizontal condensate vent
0.3
-
Chinese hat-shaped vertical vent terminal
4.7
-
Vent grille
-
2.5
Split duct chimney
5.6
4.1
Air diaphragm
Neoprene gaskets
Air intake stub
pipe
Flue gas vent
stub pipe