________________________________________________________________________________
30
AST 14 C 259/00
Modulation with P2
≠
0
DHW Output Power
During domestic hot water production, flow water temperature is always monitored and,
once 90 °C are reached, flame control section consensus will be disabled. As soon as flow
water temperature reaches 85 °C, flame control section will be enabled again.
Modulation parameter summary:
DHW temperature pre-selection range:
35 °C-50 °C
DHW thermostat triggering temperature OFF: 58°C
fixed
DHW thermostat triggering temperature ON: 53°C
fixed
DHW thermostat triggering temperature OFF
with solar (P6 = 1):
58°C fixed
DHW thermostat triggering temperature ON
with solar (P6 = 1):
57°C fixed
Flow water thermostat triggering temperature with DHW OFF: 90°C
Flow water thermostat triggering temperature with DHW ON: 85°C
Summary of Contents for Nova Florida DELFIS CTFS 24 AF
Page 51: ......