28
KC 32/KRB 32/KR 32
Max. output
Min. output
30% load
Casing heat loss with burner on
%
0.99
5.06
-
Casing heat loss with burner off
%
0.22
Flue system heat loss with burner on
%
2.61
2.04
-
Flue system mass capacity
g/s
15.81
1.87
-
Flue gas temp. – air temp.
°C
60
40.5
-
Maximum heat output efficiency rating (60/80°C)
%
96.8
-
-
Maximum heat output efficiency rating (30/50°C)
%
106.2
-
-
Minimum heat output efficiency rating (60/80°C)
%
-
92.9
-
Minimum heat output efficiency rating (30/50°C)
%
-
104.8
-
30% heat output efficiency rating
%
-
-
108.3
Efficiency rating (according to 92/42/EC)
-
NO
x
emission class
-
5
Table 17 - Combustion specifications, KC 32/KRB 32/KR 32 model
KC 28/KRB 28/KR 28
Max. output
Min. output
30% load
Casing heat loss with burner on
%
1.4
5.7
-
Casing heat loss with burner off
%
0.25
Flue system heat loss with burner on
%
2.4
2.0
-
Flue system mass capacity
g/s
13.93
1.47
-
Flue gas temp. – air temp.
°C
60
45
-
Maximum heat output efficiency rating (60/80°C)
%
96.4
-
-
Maximum heat output efficiency rating (30/50°C)
%
105.5
-
-
Minimum heat output efficiency rating (60/80°C)
%
-
92.3
-
Minimum heat output efficiency rating (30/50°C)
%
-
104.5
-
30% heat output efficiency rating
%
-
-
107
Efficiency rating (according to 92/42/EC)
-
NO
x
emission class
-
5
Table 16 - Combustion specifications, KC 28/KRB 28/KR 28 model