background image

3

1.   CHARACTERISTICS 

1.1.  Characteristics of the appliance 

IPX4 : appliance protected against splashing water 

 

Class II: double insulation 

1.2.  Technical characteristics of the electronic part

Power supply 

230V +/-10% AC 50 Hz

Electrical resistor capacity 

Mod. FD5806

600 W

Mod. FD5810

1000 W

Mod. FD5812

1200 W

Mod. FD5815

1500 W

Mod. FD5818

1800 W

Mod. FD5820

2000 W 

Insulation class

Class II

Water protection rating

IPX4

Operating temperature

0 ÷ 40°C

Storage temperature

-20 ÷ 80°C

Relative humidity

RH 0 ÷ 85% without condensate

Regulation type 

Proportional integral

Temperature range 

7° ÷ 35°C

Temperature reading resolution

1/16°C

Maximum range

0.5°C

Maximum deviation 

1.5 °C 

 

2.  

DESCRIPTION AND TECHNICAL SPECIFICATIONS OF THE PRODUCT

The radiator has a die-cast EN AB 46100 aluminium alloy body containing a fluid to transmit heat internally. This fluid is made up of highly refined 
mineral oil with a high heat transmission coefficient, characterized by high oxygenation resistance for durability and low viscosity. 

The internal fluid is heated by means of an electrical resistor with class II insulation, which has a control thermostat and safety thermal fuse.

The control and regulation electronics make it possible to regulate the ambient temperature with great precision. 

On the left-hand side there is a receptacle for distilled water used to humidify the environment.

NB: All Fondital radiators are manufactured with an identifying label which guarantees their traceability. 
This label certifies that the appliance complies with European directives and electrical standards. 

The appliance must be installed according to accepted practice, in accordance with current standards and the 
instructions contained in this manual.

Radiator colour: RAL 9010. 

 

Summary of Contents for BLITZ FD_

Page 1: ...INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_ Aluminium electric radiators with heat transfer fluid GB IST 03 F 017 01...

Page 2: ...n location THE PACKAGE INCLUDES Aluminium radiator fitted with a thermostat with electronic regulation kit made up of three mounting brackets with wall plugs and instruction manual CONTENTS 1 CHARACTE...

Page 3: ...m alloy body containing a fluid to transmit heat internally This fluid is made up of highly refined mineral oil with a high heat transmission coefficient characterized by high oxygenation resistance f...

Page 4: ...s included All work required on the appliance must be performed by a qualified professional Repairs which require opening the liquid reservoir must be made by the manufacturer its representatives or c...

Page 5: ...ounting brackets included with the appliance The mounting system consists of When mounting follow the steps illustrated below x2 x2 x2 x3 x1 x3 x3 1 2 Number of sections 5 7 9 11 12 14 Dimension A 160...

Page 6: ...can only be conside red finished when the lower screw has been comple tely tightened and the radiator is firmly attached to the wall with no possible movement The minimum distance between the radiato...

Page 7: ...be isolated Never connect it to the earth lead for any reason A multi pole circuit breaker must be installed The distance between the contacts must be at least 3 mm The appliance s power circuit must...

Page 8: ...installed in areas 2 and 3 see figure 1 on condition that the control device is not within reach of people using the shower or bathtub The radiator must not be connected to the earth lead In the bath...

Page 9: ...eating mode and the room temperature has not yet reached the desired tempe rature programmed by the user the LED is RED Once the room reaches the programmed temperature the LED turns GREEN 6 2 Changin...

Page 10: ...2 4 6 8 10 12 14 16 18 20 TL TH THERMOMETER TEMPERATURE TIME 6 4 Setting times and weekly programming Press the stand by and mode keys at the same time and hold for three seconds A dot will blink on t...

Page 11: ...m day 1 select the times when the TH temperature is desired Pressing the key activates the segment on the screen and therefore TH as well Pressing the key deactivates the segment and the programmed te...

Page 12: ...trol centre 6 6 3 Comfort mode This is the normal mode when the radiator is in use keeping the ambient temperature at the programmed level 1 Press the mode key until the screen displays the icon 2 Sel...

Page 13: ...weekly programming which sets the two temperature levels Comfort and Night time defined by the user for each time of day Pilot wire The temperature depends on the Pilot Wire control for radiators ins...

Page 14: ...vel Check the temperature program med The room does not get hot enough in Comfort mode LCD lit in the desired mode The radiator is not large enough for the size of the room Replace the radiator with o...

Page 15: ...ic compatibility DIRECTIVE 2002 96 CE of 27 January 2003 on waste from electrical and electronic equipment WEEE And in accordance with the following harmonized regulations EN 60335 1 2004 04 safety of...

Page 16: ...65 878 31 Fax 39 0365 878 576 e mail info fondital it www fondital it The manufacturer reserves the right to modify the products as it deems necessary and useful without affecting their basic features...

Reviews: