ADJUSTMENT AND PROGRAMMING
The control panel has two controls: the one on the left to select operating
mode and the one on the right to program room temperature.
Operating mode control
Temperature control
LED
fig. 2
There is also a LED light which turns green when room temperature reaches the value set by the user, and red when room temperature is below
set value with fed heating element.
There are five operating modes: Comfort, Night reduction, Antifreeze, Stand-by, Pilot wire.
Comfort mode
This function allows for room temperature adjustment.
It is the radiator’s normal use to keep room temperature at set value. Set temperature depends on temperature control position.
Indicatively, the correspondence between set temperature and the numbers indicated in the control is as follows:
With rotation angle of 0º to 9.5º, set temperature is of about 7 ºC.
22 C
4
2
6
8
30 C
15 C
7 C
9,5
fig. 3
Antifreeze mode :
By selecting this mode the set room temperature is of 7 ºC.
Night Reduction mode :
If the mode control is in this position, set temperature will be 3..5 ºC less than the one programmed on temperature control at that time.
Pause position :
When mode control is in this position, all functions are disabled and the radiator does not warm up the room.
The LED remains off.
Warning: in this position, the radiator is still being electrically powered.
Pilot wire mode :
This mode allows for radiator management using a remote control unit.
Temperature setting depends on pilot cable controls and on temperature potentiometer position.
This mode can only be used on radiators installed in France.