background image

18

Finishing plug

00105536

Not shown

Leveling leg

00103432

19

Strain relief, power cord

00105403

20

Temperature controller

00103358

21

Control relay retrofit kit (from clear plastic relay)

00133264

21

Control relay (retrofitted refrigerators)

00133272

22

Power cord

00103903

23

Socket (each – 2 required)

00103887

24

Power switch, flush mount (before svc# B28296)

502209

Power switch, recessed mount (after svc# B28296)

00114371

Not shown

Strain relief, wiring, front panel

00105577

14

Reference #

Description

Part #

1

Door, REF5 (includes gasket)

00105015

Not shown

Door, REF4-ADA (includes gasket)

00113910

2

Latch & striker (includes screws)

00105023

3

Latch screws (each – 3 per latch)

00103507

4

Striker screws (each – 2 per striker)

502287

5

Hinge (each – 2 required, includes screws)

00105031

6

Hinge screws (each – 6 per hinge)

00105080

7

Strip sealer (set of 4)

00105049

8

Gasket, REF5 (21 5/8" x 21 5/8" door)

00103291

Not shown

Gasket, REF4-ADA (18 5/8" x 21 5/8" door)

00108092

9

Shelves (each)

00103283

10

Pilaster (each)

00105346

Not shown

Thumb screws (set of 8)

00105353

11

Shelf support (snap-in, each)

00105361

12

Lower front panel (includes 00114371 and screws)

00105056

13

Front panel screws (each – 6 per panel)

00105379

14

Rear panel (includes screws)

00105064

15

Rear panel screws (each – 6 per panel)

00105387

16

Condensate tray (includes screws & spacers)

00103275

Not shown

Key

00105072

17

Spacer, condensate pan

00105098

Not shown

Seal, bushing, rear panel

00114512

Electrical components

3

1

4

5

6

9

10

11

12

13

7

rear cutaway

8

16

14

15

2

23

21

22

19

20 24

18

17

Hardware

Summary of Contents for Symphony REF Series

Page 1: ...nt 00104109R09 801 Church Lane PO Box D Easton PA 18044 USA Toll free 800 523 9361 888 2 FOLLETT 610 252 7301 Fax 610 250 0696 www follettice com UL Following installation please forward this manual to the appropriate operations person UL C Order parts online www follettice com Before service number B59000 ...

Page 2: ... 4 The equipment must be returned in Follett packaging If the packaging has been damaged or discarded Follett will forward at the customer s expense new packaging Note Return freight charges are the responsibility of the customer If equipment is returned and is damaged because of improper packaging Follett Corporation will not be held responsible Credit will be issued when The equipment has been i...

Page 3: ...ng door 5 Changing the temperature set point 6 Operation 7 How the refrigerator works 7 Temperature control 7 Defrosting 7 Cleaning 7 Service information 8 Latch adjustment 8 Gasket replacement 8 Slide out compressor tray 8 Wiring diagram 8 Refrigeration system diagram 9 Troubleshooting guide 10 Accessory information 11 Temperature alarm 11 Pyxis 12 Replacement parts 13 3 ...

Page 4: ... so that we can help in the filing of a claim if necessary Specifications Series specifications REF4 ADA 31 5 height fits below 34 high ADA compatible counter 4 0 cu ft capacity REF5 34 5 height fits below standard 36 high counter 4 8 cu ft capacity Electrical specifications 115V 60Hz 1 phase Full load amps 8 0 Minimum circuit ampacity 15 amp Maximum size of branch circuit overcurrent device 15 am...

Page 5: ...g bottom tab up and out of pilaster 3 Insert each shelf bracket in new location by inserting top curved tab and applying pressure while inserting lower tab 4 Reinsert shelf Reversing the door swing optional 1 Remove screws and latch from refrigerator cabinet Fig 1 1 2 Use flat screwdriver to carefully remove do not scratch hinge covers Fig 2 1 3 Support door and remove screws attaching hinge to re...

Page 6: ...4 3 4 Press SET Fig 4 4 The characters on the display will disappear for a moment Fig 4 5 and then display the current temperature Fig 4 6 The new set point is now accepted Note See Fig 5 for examples of temperature ranges by set point Fig 5 Examples of temperature ranges by set point Set point Cut in Cut out Normal temperature display range 38 38 34 32 38 39 39 35 33 39 40 40 36 34 40 41 41 37 35...

Page 7: ...ut in temperature of the controller can be raised to as high as 50 F by following the instructions on page 6 for changing the temperature set point The 3 F cut out differential will be maintained regardless of the controller set point Defrosting REF Series undercounter refrigerators do not require manual defrosting The unit cooler defrosts automatically when the condensing unit is in the OFF cycle...

Page 8: ... Fig 8 1 2 Remove the two screws and spacers securing the condensate pan and set the pan aside Fig 8 2 3 Remove the two bolts securing the condensing unit to the refrigerator base Fig 8 3 4 Gently slide the condensing unit out Fig 8 4 Note Do not put undue strain on the refrigerant lines Wiring diagram Note 1 Highlighted area on wiring diagram indicates jumper included on refrigerators with servic...

Page 9: ...stem by pressures Checking refrigeration system pressures 1 Remove the rear access panel Fig 8 2 Turn the power switch to the on position 3 Following the instructions on page 6 verify that the temperature controller is set to the original factory cut in setting of 38 F 4 Allow the refrigerator to operate and stabilize at least 30 minutes verifying the cut out temperature is being reached 5 Connect...

Page 10: ...er 4 Check controller contact terminals for power Replace controller if needed 5 Replace relay 6 Replace controller and or probe 1 Reconnect power cord 2 Replace relay 1 Allow to cool or replace 2 Replace as required 3 Replace compressor 1 Reconnect power cord 2 Replace relay 3 Replace fan motor 1 Replace controller and or probe 2 Replace controller 3 Replace control relay 1 Clean coils as needed ...

Page 11: ... temperature has returned to set range 3 4 Audible alarm on No audible alarm 3 Enables 5 min alarm snooze Enables 45 min alarm snooze when reset button is pressed with 4 on when reset button is pressed with 4 off Fig 10 Fig 11 Installing alarm 1 Mount alarm in desired location with screws supplied by others through back of housing Do not place undue strain on probe cable Note Do not modify length ...

Page 12: ... selected range During power failure the alarm face will be dark but temperatures can be read by pressing the RESET button To see the highest or lowest temperature since last reset press the button until HI or LOW appears To clear log value press RESET Because the temperature alarm display simulates the true temperature of stored medications rather than the air temperature inside the refrigerator ...

Page 13: ...ting capacitor 00104968 Not shown Starting relay 00104976 Not shown Overload protector 00104984 9 Condenser fan motor 00104992 10 Condenser fan blade 00105007 11 Condensing unit 00105106 12 Wiring strain relief 00105577 13 Condenser 00105619 Not shown Cap starting capacitor 00105627 14 Drain tube evaporator includes clamp 00121681 Replacement parts Refrigeration Evaporator Reference 5 Condensing u...

Page 14: ...0103507 4 Striker screws each 2 per striker 502287 5 Hinge each 2 required includes screws 00105031 6 Hinge screws each 6 per hinge 00105080 7 Strip sealer set of 4 00105049 8 Gasket REF5 21 5 8 x 21 5 8 door 00103291 Not shown Gasket REF4 ADA 18 5 8 x 21 5 8 door 00108092 9 Shelves each 00103283 10 Pilaster each 00105346 Not shown Thumb screws set of 8 00105353 11 Shelf support snap in each 00105...

Page 15: ...des battery probe and power supply 00108175 Not shown Gasket bottle 00112029 Not shown Bracket bottle 00112011 Not shown Bottle 00112037 Not shown Battery 00112177 Not shown Screws includes two for securing cover 00115063 Not shown Label controller cover 00115071 Not shown Temperature probe 00115097 Pyxis accessory Not shown Pyxis door bracket 00114702 ...

Page 16: ...Cool Ideas For Ice Management 00104109R09 02 05 801 Church Lane PO Box D Easton PA 18044 USA Toll free 800 523 9361 888 2 FOLLETT 610 252 7301 Fax 610 250 0696 www follettice com UL UL C ...

Reviews: