background image

Refrigeration pressure data

Air-Cooled ice machine capacity/24hrs

Ambient Air Temperature F/C

Inlet 

W

at

er T

emper

atur

F/C

F

60

70

80

90

100

C

16

21

27

32

38

50

418

388

357

325

294

lbs.

10

189

176

162

147

179

kg.

60

395

370

345

313

281

lbs.

16

179

168

156

142

127

kg.

70

372

353

334

301

268

lbs.

21

169

160

151

137

122

kg.

80

362

340

318

288

259

lbs.

27

164

154

144

131

117

kg.

90

352

327

302

275

249

lbs.

32

160

148

137

125

113

kg.

Compressor data

Air-cooled
Ambient air temperature

50 F/10 C

70 F/21.1 C

90 F/32.2 C

110 F/43.3C

230 V

230 V

230 V

230 V

Amperage

2.2

2.3

2.5

2.6

High-side pressure (PSIG)

112

152

202

260

Low-side pressure (PSIG)

18.5

21

25

30

Locked rotor amps: 

230 V: 18.2A

Gearmotor data

Gearmotor data

230 V/50 Hz

Gearmotor current

1.3A (nominal)

Refrigeration system

 

Caution: Risk of fire.

Important: All service on refrigeration system must be performed in accordance with all federal, state and 

local laws that pertain to the use of refrigerants. It is the responsibility of the technician to ensure that these 

requirements are met.

R414 ice machine charge specifications

Model

Charge

Refrigerant type

E12CI414A (air-cooled)

3.52 oz (100 grams)

R290

E12CI414A R290, 230 V 50 Hz

Summary of Contents for Symphony Plus 12 Series

Page 1: ...ll packing material Inspect the equipment for concealed shipping damage All freight is to be inspected upon delivery If visible signs of damage exist please refuse delivery or sign your delivery receipt damaged Follett Customer Service must be notified within 48 hours Wherever possible please include detailed photos of the damage with the original packaging so that we may start the freight claim p...

Page 2: ...ke product improvements at any time Specifications and design are subject to change without notice Do not tilt unit further than 30 off vertical during uncrating or installation Dispenser bin area contains mechanical moving parts Keep hands and arms clear of this area at all times If access to this area is required power to unit must be disconnected first This appliance is not suitable for install...

Page 3: ...Bar Max 10 psi 0 7 Bar Min Ambient air temperature is measured at the air cooled condenser coil inlet Ambient water temperature is measured in the ice machine reservoir Plumbing 12CI414A Dispenser drain 3 4 MPT Water inlet 3 8 FNPT Note Water shut off recommended within 10 ft 3 m of dispenser Drain to be hard piped and insulated Maintain at least 1 4 per foot 20 mm per 1 m run of slope Ventilation...

Page 4: ... F 21 1 C 90 F 32 2 C 110 F 43 3C 230 V 230 V 230 V 230 V Amperage 2 2 2 3 2 5 2 6 High side pressure PSIG 112 152 202 260 Low side pressure PSIG 18 5 21 25 30 Locked rotor amps 230 V 18 2A Gearmotor data Gearmotor data 230 V 50 Hz Gearmotor current 1 3A nominal Refrigeration system Caution Risk of fire Important All service on refrigeration system must be performed in accordance with all federal ...

Page 5: ...gh back or bottom of dispenser drill four 7 16 holes in counter to anchor dispenser to counter Fig 1 3 For utilities exiting through bottom only a Make cut out Fig 1 b Move drain fitting from back of dispenser and mount Fig 2 c Cut drain tube to length and attach to barbed connection d Move inlet water fitting from back of dispenser and mount Fig 2 e Cut water tubing to length and re insert into w...

Page 6: ...es be reviewed with the appropriate infectious agent subject matter experts to assure complete remediation Periodic cleaning of Follett s ice and water dispenser and ice machine system is required to ensure peak performance and delivery of clean sanitary ice The recommended cleaning procedures that follow should be performed at least as frequently as recommended and more often if environmental con...

Page 7: ...it under top front cover 2 Clean lens and splash panel front using a soft cloth and mild non abrasive non chlorine based cleaner 3 Reactivate dispensing by pressing and releasing clean switch again Monthly CAUTION Do not use solvents abrasive cleaners metal scrapers or sharp objects to clean any part of the dispenser Condenser air cooled ice machine only Use a vacuum cleaner or stiff brush to care...

Page 8: ... storage hopper b Remove stud assembly baffle wheel and any remaining ice c Remove dispense chutes from splash panel d Submerse drain grille in SafeCLEAN Plus solution and allow to soak to remove any scale buildup e Wipe inside of hopper lid stud assembly baffle wheel inside of storage area dispense chutes drain grille and drain pan with damp cloth wrung out in SafeCLEAN Plus solution Thoroughly r...

Page 9: ...or OFF Legend OFF ON 1 Ice machine is making ice 1 Normal running 2 Ice machine is not making ice 2 Normal time delay When the bin fills with ice the LOW BIN light goes out momentarily and the refrigeration and auger drive systems immediately shut down Note The fan motor will continue to run for 10 minutes to cool condenser The TIME DELAY light comes on initiating the time delay period When the ti...

Page 10: ...Wiring diagram 230 V 50 Hz 10 E12CI414A R290 230 V 50 Hz ...

Page 11: ...E12CI414A R290 230 V 50 Hz 11 ...

Page 12: ...nse water 1 Faulty water solenoid valve 2 Faulty dispense switch 3 Power switch off or faulty 1 Replace water solenoid valve 2 Replace dispense switch 3 Check switch turn on or replace if faulty SensorSAFE model troubleshooting guide Problem Action SensorSAFE Board LED Status Corrective Action PWR CLN ICE WTR Does not dispense ice and or water Check LEDs on the SensorSAFE control board OFF OFF OFF...

Page 13: ...maximum efficiency Follett LLC will not be liable for any consequential damages expenses connecting or disconnecting charges or any losses resulting from a defect of the machine For full warranty details visit our website www follettice com productwarranties Registering your equipments helps Follett track your equipment s service history should you need to contact us for technical support and your...

Page 14: ...14 E12CI414A R290 230 V 50 Hz ...

Page 15: ...E12CI414A R290 230 V 50 Hz 15 ...

Page 16: ...oll free 877 612 5086 1 610 252 7301 www follettice com Calgon is a licensed trademark distributed by Nu Calgon in the United States Dow Corning is a registered trademark of Dow Corning Corporation in the United States and other countries SafeCLEAN SaniSponge SensorSAFE and Symphony Plus are trademarks of Follett Products LLC Follett is a registered trademarks of Follett Products LLC registered in...