Maestro Plus
5
2.
Site Preparation
Provide drainage, potable water supply and electrical power to within 6 feet (2m) of
ice machine in accordance with local and national codes. Outdoor installation is not
recommended and will void warranty.
2.1
Installation site requirements
➋
➌
➊
➍
5-15
NEMA
1/4"
1'
➍
Electrical
➊
WARNING!
§
This appliance should be permanently connected by a qualified person in accordance with application codes.
§
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
MCD425(A/W)VS* 115/60/1 (115 V ±10%), 15A breaker
* Requires a 15A dedicated circuit.
Potable Water Supply
➋
10 psi to 70 psi (69 kpa to 483kpa)
45 F to 90 F (7 C to 32 C)
Condenser water supply for water-cooled systems
➌
10 psi min.; 125 psi max. (69 kpa min.; 862 kpa max.)
20 F to 90F (–7 C to 32 C)
0.5 gallons (1.9 liters) per minute
Drain
➍
The drain line from the ice machine must have at least 1/4 in. per foot (6,4 mm/0,3 m) pitch