background image

Side view — air-cooled and water-cooled

20.75" (52.7 cm)

22.75" (57.8 cm)

17.00"

(43.2 cm)

RIDE model air-cooled units only

Front view — top mount

MCE425A/W_T
MFE425A/W_T

MCE425A/W_S
ER425A/W

Side view — top mount

22.49" (57.1 cm)

21.29" (54.1 cm)

22.69" (57.6 cm)

22.46" (57.1 cm)

Back view — top mount

A

B

D

E

C

Front view — water-cooled

CONDENSER

OUTLET

10.62" (27.0 cm)

8.25" (20.9 cm)

4.81"

(12.0 cm)

2.31"

(5.7 cm)

5.25"

(13.3 cm)

C

F

E

D

A

B

Front view — air-cooled

4.81"

(12.0 cm)

2.31" (5.7 cm)

2.5" (6.4 cm)

C

F

A

B

18.88" (48 cm)

18.88" (48 cm)

2.32"

(5.9 cm)

4.40" (11.2 cm)

15.22" (38.7 cm)

11.03" (28.0 cm)

8.03" (20.4 cm)

5.03" (12.8 cm)

2.34" (6 cm)

Dimensions and clearances

 

§

Entire front of ice machine must be clear of obstructions/connections to allow removal.

 

§

12" (30.5 cm) clearance above ice machine for service.

 

§

6" (15.3 cm) minimum clearance between exhaust side of ice machine and any adjacent equipment.

 

§

MCE425A and ER425A  – 18" (45.7 cm) minimum, 10 ft (3 m) maximum clearance between discharge and air  
intake grilles.

A – 3/4" MPT drain
B – 3/8" FPT water inlet
C – Electrical cord

D – 3/8" FPT condenser inlet
E – 3/8" FPT condenser drain
F – Bin signal connection (DO NOT APPLY VOLTAGE!)

  

MC_425A/W, MM_425A/W, MF_425A/W, _P425A/W Ice Machines 5

Summary of Contents for Maestro Plus CP425A

Page 1: ...e Getting Started After uncrating and removing all packing material Inspect the equipment for concealed shipping damage All freight is to be inspected upon delivery If visible signs of damage exist pl...

Page 2: ...way and understand the hazards involved Children should be supervised to ensure that they do not play with the appliance This appliance is designed for commercial use WARNING To avoid a hazard due to...

Page 3: ...e 90 F 32 2 C max 45 F 7 2 C min Condenser water pressure 125 psi 862 kPA max 10 psi 68 kPA min Ambient air temperature is measured at the air cooled condenser coil inlet Ambient water temperature is...

Page 4: ...220 V 230 V Amperage 2 8 2 4 2 9 2 5 2 9 2 5 2 9 2 5 3 0 2 6 High side pressure psi 290 290 291 291 292 292 292 293 293 294 Low side pressure psi 31 32 31 32 32 33 32 34 33 34 Locked rotor amps 220 V...

Page 5: ...48 cm 18 88 48 cm 2 32 5 9 cm 4 40 11 2 cm 15 22 38 7 cm 11 03 28 0 cm 8 03 20 4 cm 5 03 12 8 cm 2 34 6 cm Dimensions and clearances Entire front of ice machine must be clear of obstructions connectio...

Page 6: ...at this cleaning is performed according to the schedule below Service problems resulting from lack of preventive maintenance will not be covered under the Follett warranty Recommended cleaning interva...

Page 7: ...uart until SafeCLEAN Plus solution completely fills the reservoir Place lid back on cup 6 CLEANER FULL light will turn on and machine will start cleaning cycle then rinse three times this process take...

Page 8: ...xpires the machine will restart provided that the LOW BIN light is on DIP Switch Settings OFF POSITION ON POSITION MCE425A W_T MCE425A W_S ER425A W 425A W installed in Symphony Plus 25 50 110 CI CT or...

Page 9: ...MC_425A W MM_425A W MF_425A W _P425A W Ice Machines 9...

Page 10: ...10 MC_425A W MM_425A W MF_425A W _P425A W Ice Machines...

Page 11: ...MC_425A W MM_425A W MF_425A W _P425A W Ice Machines 11...

Page 12: ...d services backed by outstanding customer and technical support Please review the installation instructions thoroughly It is important that the installation be performed to factory specifications so y...

Reviews: