1
2
3
4
Fig. 6
5. Remove transfer case with two latches (Fig. 6.1).
6. Remove ice deflection plate by lifting up (Fig. 6.2).
7. Remove auger by lifting up (Fig. 6.3).
8. Remove auger tube by lifting up. Note position of locating
slot on lower end for reinstallation (Fig. 6.4).
9. Remove blower duct by loosening thumb screw, rotating
clip (Fig. 7.1) and lifting up (Fig. 7.2).
1
2
Fig. 7
10. Remove control box/fan motor mounting assembly with
two screws (Fig. 8).
Fig. 8