20
HCD710A, HMD710A
Fig. 17
10. Remove front feed water tube from push-in fitting,
shuttle drain tube, and shuttle switch.
Fig. 18
11. Remove 3 screws (with 3/16" allen wrench) then
remove auger and main housing together.
Note: Auger is sharp - wear protective gloves.
Fig. 19
12. Rotate auger to align opening in auger flange with
stream divider.
13. Pull out auger.