Undercounter Dispenser and Ice machine E7UC100A/E7UD100A
7
Installation ––––––––––––––––––––––––––––––––––––––––––––––––––––––
CAUTION!
No service or maintenance should be performed until the technician has thoroughly read this
service manual. Except for routine cleaning and sanitizing, only qualifi ed technicians should
attempt to service or maintain this equipment.
1.
Measure to verify that the dispenser will fi t in the desired
location. A clearance of at least 3" (77 mm) is required behind
the dispenser for the electrical and optional drain connection.
2.
Ensure that the fi nished fl oor inside the cabinet is fl ush (level)
with the fl oor outside the cabinet
(Fig. 1)
. If the cabinet fl oor
is lower than the fi nished fl oor, the cabinet fl oor must be
built up (using appropriate materials) until it is fl ush with the
fi nished fl oor. A fl ush fl oor is required for proper operation and
maintenance/service of the dispenser.
3.
Rough-in the electrical service, water line, and optional Drip
Tray Drain Kit*.
Note:
The dispenser must be installed such that it can be moved
forward at least 4" (10.15 cm) to allow access to the Bin
Lid Cleaning Spout
(Fig. 9.6)
for dispenser cleaning and
sanitizing. Take this requirement into consideration during
rough-in.
§
Electrical: 115V, single phase, 15A receptacle required. The
dispenser has an integral 8 ft. (2.4 m) cord and plug.
§
Water: supply line (with shut-off valve) connects to the dispenser's
1/4" MPT inlet.
*
The optional Drip Tray Drain Kit (item# 00956375) requires a fl oor drain
within 15 ft. (4.5 m) of the dispenser. For detailed installation instructions,
please refer to the instructions shipped with the Drip Tray Drain Kit.
Fig. 1
cabinet space
floor
4.
Install the angle bracket inside the cabinet,18.15" (461 mm)
from the toe kick
(Fig. 2.1).
The bracket prevents the dispenser
from being located/pushed beyond the recommended cabinet
space depth.
Do not attach the bracket to the dispenser.
Fig. 2
46.1 cm (18.15")
1