8
Dimensions and clearances
220/60 models
Entire front of ice machine must be clear of obstructions/connections to allow removal.
305mm (12") clearance above ice machine for service.
153mm (6") minimum clearance between exhaust side of ice machine and any adjacent equipment.
MCC400A & C/ER400A – 457mm (18") minimum, 3m (10 ft) maximum clearance between discharge and air intake
grilles.
17.00"
(432 mm)
17.00"
(432 mm)
18.875" (480 mm)
1" (26 mm)
12.9"
(328 mm)
5"
(127 mm)
12.7"
(323 mm)
17.00"
(432 mm)
18.875" (480 mm)
2.25"
(57 mm)
8.375"
(213 mm)
4.75"
(121 mm)
12.875"
(327 mm)
Side View –
water-cooled
Front View –
water-cooled
Side View –
air-cooled, RIDE model
Front View –
air-cooled, RIDE model
NSF
R
R
U
L
U
L
20.75" (527 mm)
17.00"
(432 mm)
C
C
E
D
F
F
B
B
A
A
7.00" (178 mm)
1.875" (48 mm)
2.25"
(57 mm)
8.375"
(213 mm)
4.75"
(121 mm)
12.875"
(327 mm)
22.75" (578 mm)
20.75" (527 mm)
A
– 3/4" MPT drain
B
– 3/8" OD push-in water inlet
C
– 2" x 4" (51 mm x 102 mm) electrical box
D
– 3/8" FPT condenser inlet
E
– 3/8" FPT condenser drain
F
– Bin signal cord