background image

08

.INSTALLATION OF ZERO FRAME

Fix the frame on the wall with the appropriated screws (screws are not given by

us).

Use 24V power supplies

Use power supplies with the correct Wattage with regards to what indicated on the

label positioned on the back of each FOLIO® LED panel.

Pay particular attention to the data on the label before connection the appliance to the

mains.

IN CASE OF MALFUNCTION, DISCONNECT THE APPLIANCE.

Use class II drivers with adequate absorption with regards to the consumption of the

FOLIO® panel, with an exit current of 24V and with SELV exits EN 61347-2-13 compliant.

It is recommended to connect maximum 4/5 FOLIO® panels to one driver.

.POWER SUPPLIES

FOLIO

®

SINGLE PANEL

FOLIO

®

TWO OR MORE PANELS

FOLIO

®

24V

Panel

FOLIO

® Panel

FOLIO

® Panel

220V

220V

Ceiling fixing follows the same procedure.

24V

POWER SUPPLY

Summary of Contents for ZERO40

Page 1: ...ZERO40 USER MANUAL Remote power supply ceiling wall 25 ENG ZERO U S E R M A N U A L trasformatore remoto soffitto parete...

Page 2: ...tion FOLIO 12 Electrical connection 13 panel fixing FOLIO 15 Cloth positioning 17 Power supplies 18 WARNING 19 Handling 20 Cleaning 21 Damaged appliances 22 Dismantlement ZERO 55 50 FOLIO panel Telo P...

Page 3: ...05 COMPONENTS Inside the packing crate you will find FOLIO LIGHTING PANEL ZERO PROFILES CORNERS WIDTHS CLOTH with or without print ZERO80 PROFILES CLOTH PRINTED WIDTHS FOLIO LIGHTING PANEL CORNERS 05...

Page 4: ...06 COMPOSITION OF ZERO FRAME Positon the profiles at 45 and connect the angles screwing the corners Tighten the grains in all four corners until creating the frame ZERO...

Page 5: ...he installation of the FRAME use only 6 8 mm diameters screws DON T use dif ferent fixing systems like whashers because could be visible once finished the installa tion NO YES Zero Frame with washers...

Page 6: ...08 INSTALLATION OF ZERO FRAME Fix the frame on the wall with the appropriated screws screws are not given by us Ceiling fixing follows the same procedure...

Page 7: ...09 INSTALLATION OF ZERO FRAME 5 Pass the 24V 6 electric cable previously installed by you into the ZERO frame After fixing the ZERO frame verify if it is symmetrical and squared 6...

Page 8: ...STALLATION OF ZERO FRAME 7 Extend the extension of electric cables by fixing them according to the cables output of the FOLIO lighting panel s 8 Clean the residual particle inside the duct of ZERO pro...

Page 9: ...ng the holes Widths supplied by us and already equipped with double sided adhesive for panel application Position the FOLIO panel s inside the ZERO frame inserting from the bottom Pay attention to not...

Page 10: ...h the red cable of the driver and the black cable of the LED to the black cable of the driver Subsequently connect the driver to the electrical system with the 110 V cable and power the system Use cla...

Page 11: ...13 FOLIO PANEL FIXING Place the width at the point where the panels will be joined and fix the light panel with appropriated screws screws not supplied Be careful not to over tighten the screws...

Page 12: ...14 FOLIO PANEL FIXING Proceed with the installation of the remaining panel s in the same way...

Page 13: ...15 CLOTH POSITIONING Position the fabric with the eventual print to the outside...

Page 14: ...16 CLOTH POSITIONING Insert the seal in all four sides of ZERO frame and tense the fabric...

Page 15: ...appliance to the mains IN CASE OF MALFUNCTION DISCONNECT THE APPLIANCE Use class II drivers with adequate absorption with regards to the consumption of the FOLIO panel with an exit current of 24V and...

Page 16: ...C Keep away from heat sources Do not expose to direct sunlight Keep away from combustible substances Avoid contact with vapors fumes dust gas and liquids Avoid accumulation of electrostatic charges A...

Page 17: ...ly Carry the FOLIO panel vertically to prevent every possibility of bending and curving Pay attention not to pull the power cables Do not use suction cups for the handing or installation of the FOLIO...

Page 18: ...ssione ATTENZIONE non passare il panno in prossimit della striscia LED illuminante NOTICE DO NOT SPRAY OR POUR DIRECTLY ON THE PANEL ANY TYPE OF CLEANING AGENT BUT DISTRIBUTE THE CLEANING AGENTS LIQUI...

Page 19: ...fore proceeding with visual inspections trials or maintenance operations on this appliance disconnect all current and voltage sources Proper functioning of this appliance depends on the correct operat...

Page 20: ...e and some others may be harmful In accordance with Italian LEGISLATIVE DECREE 14 March 2014 no 49 in the field of electric and electronic appliances we inform you that the appliance this instruction...