background image

Lift overview 

(see Illustration A) 

Make sure page 2 in this manual is completed by the dealers installation service.  

 

  1      spa cabinet 

  2      drive cap 

  3      quick lock screw M12 allen 

  4      foldaway drive 

  5      carbon support  

  6      carriage mechanism 

  7      circlip (securing clip)  

  8      cover dowel  

  9 

cover hinges 

10      coded smart key  

11      smart key docking station 

12      foldaway control box 

13 

infrared remote control (optional) 

System description 

The foldaway lift controller is designed for driving two self locking 24V DC actuators in parallel by 

applying pulse width modulated signals (PWM) at a frequency of 16kHz. This high frequency gives 

the systems it´s high efficiency, low noise and low power stage loss. 

The drive is synchronized with actuator pulse feedback signals. The synchronization is achieved by 

adjusting actuator speed during drive. If the adjustment can not compensate the unbalance 

between the actuators, both motors stop.  

The logic board monitors current limits, position sensor data and the power stage temperature limit. 

The basic lift control is done with open and close commands from the smart key panel. Any 

additional command after lift utilization stops the driving without time delay.  

The automatic cover realignment makes the foldaway lift a fit and forget system without special 

maintenance tasks. 

All programmed routines are microprocessor controlled, the system takes over control at defined 

steps in the cover movement sequence and completes the intended process without user 

interaction.  

The insulation cover rests tight as possible on the tub. No energy is lost and cover freezing is 

reduced to a minimum.  

The automatic closing routine is finished when both drives reversed after touchdown and the smart 
key illuminates in green. 

9

Summary of Contents for F1-230 V10

Page 1: ...er lift system operating manual V 1 5 Model F1 230 V10 European version www foldaway at Document Number BEB 203 214 9 Before first use of the appliance please read these Operating Instructions and act...

Page 2: ...has been declared as a whole including the product that is subject of this declaration in conformity with legal requirements Above declarations apply to the original product only Any modification s to...

Page 3: ...Illustration A Illustration B 3 1 4 2 3 5 6 7 11 8 9 10 12 13...

Page 4: ...ustration D EMERGENCY LIFT OPERATION 1 REMOVE THE PLASTIC SECURING CLIP FROM THE COVER DOWEL ON BOTH SIDES 2 DETACH THE LIFT CARRIAGE MECHANISM FROM THE COVER ON BOTH SIDES 3 MANIPULATE AND SECURE THE...

Page 5: ...docking system 10 Cover quick release mechanism 10 Self locking drives 10 Overload protection 10 Safety controller 11 Danger areas 11 Daily Operation 12 Getting started unlock the system 12 Open the s...

Page 6: ...ments or suggestions are welcome to BEB Fertigungscenter GmbH Co KG A 2433 Margarethen am Moos B ckerstrasse 1 Austria Phone 43 0 2230 20270 130 support foldaway at Disclaimer The information containe...

Page 7: ...The packaging material can be recycled Please do not place the packaging into the ordinary refuse for disposal instead arrange for the proper recycling Old lifts contain valuable materials that can b...

Page 8: ...anical release circlip on both lift arms Make sure the area below the cover is free before pulling the circlips Removing the clips exposes the spa cover to free fall Be careful when touching dark surf...

Page 9: ...chieved by adjusting actuator speed during drive If the adjustment can not compensate the unbalance between the actuators both motors stop The logic board monitors current limits position sensor data...

Page 10: ...y depending on the current position after releasing both sides Self locking drive The drives are self locking in any position even without power supply Overload protection Each drive is equipped with...

Page 11: ...riodic self test the safety circuit continuously monitors the function of all relevant internal parts to ensure a safe operation Danger areas The foldaway lift system is able to detect certain objects...

Page 12: ...our foldaway smartphone app Make sure by visible contact that the movement area of the lift and the parking area of the spa cover is free Parts of the vinyl cover can stick to the spa surface An indic...

Page 13: ...t travel beyond programmed limits independent of commanded direction Cover Lifetime The cover lifetime monitor is a program routine that estimates the quality of thermal insulation of the cover by mea...

Page 14: ...tings allow water to infiltrate the structure In freezing outside conditions the transparent coating can chip off upon freezing of water underneath Avoid acid and caustic solutions on the carbon coati...

Page 15: ...utilization If the failure is consistent consult your customer service A red continuous illumination indicates a failure in the safety relay Please consult an authorized customer service Close the sp...

Page 16: ...l position One long beep confirms the action The LED illumination is changing to green blinking for approximately 4 seconds While in progress the LED illuminates blue The alignment is finished when th...

Page 17: ...15mm approx 1 2 inch at the tip of the arm If the distance is greater unscrew the black drive cap Check the tightness of center allen screw If the screw is loose move the arm manually forward and bac...

Page 18: ...will automatically align the lift system ________________________________________________________________________ Q My spa cover lift is working in closing direction only I cannot open the spa A The p...

Page 19: ...60Hz 150VA internal fuse 6 3A 20x5 power stage max temp 120 C drive modulation and frequency PWM 16kHz ultra low noise ambient temp Ta 20 C bis 60 C standby power 15mA CE rating EMV industrial environ...

Page 20: ...BEB Fertigungscenter GmbH Co KG B ckerstra e 1 2433 Margarethen am Moos Austria Phone 43 2230 20 270 130 Fax 43 2230 20 270 900 email support foldaway at 20...

Page 21: ...linking position data fault alignment required 180 AND within 2sec 180 green blinking system message alignment imminent blue system message obstacle detected alignment in progress internal fault clear...

Reviews: