FOGO FH 9000 User Manual Download Page 8

 

2. Safety rules 

 

 

Safety  of  the  user  and  all  persons  staying  near  to  the 
device  is  very  important.  Important  information  is 
included in the manual and on the power generator set - 
it must be read carefully. The information indicates and 
warns of potential danger for user and third parties.

 

 

The power generator produces enough power to cause a 
serious  electrical  shock  in  case  of  improper  use.  Make 
sure  that  the  power  generator  is  grounded  when 
connected    receivers  are  grounded.  For  grounding  the 
power  generator,  use  a  copper  conductor  with  cross 
section  equal  or  larger  than  the  conductor  used  to 
connect  receivers.  If  you  connect  the  receivers  having 
the  grounding,  a  grounding  cable  must  be  used. 
Grounding  rod  is  present  in  every  Fogo  generator  -  on 
the crossbar of the frame under the engine and marked.

 

 

- Before starting the power generator, read its manual and make 

sure  that  you  understand  all  its  recommendations.  Every  person 
using the power generator must read its manual.

 

 

CAUTION ! 

During operation of the device, 

the silencer reaches high temperatures and 

remains hot for some time after stopping. 

Allow the engine to cool before storing it 

indoors.

 

 

-  Do  not  operate  the  generator  in  an  enclosed 

space  without sufficient ventilation. Exhaust gases 
are  toxic  (contain  large  amounts  of  odourless 
carbon monoxide [CO]) -

 

RISK OF POISONING OR EVEN DEATH!!!

 

 

7

 

During  the  operation,  the  engine  should  be  provided 
with fresh air inflow of at least 100 m³/h (variable value 
depending  on  the  type  of  the  device  -  for  the  correct 
selection  of  ventilation,  please  contact  the  customer 
service  of  AGREGATY  S.A.).  When  using  the  power 
generator  unit  with  additional  ventilation  indoors, 
observe  the  additional  requirements  for  explosion 
protection.

 

 

- Do not fill the fuel tank while the engine is 
working - RISK OF EXPLOSION!!!

 

- Do not start the power generator in case of 
fuel spillage. Restarting is permitted after  

removing of the spilled fuel - FIRE RISK!!!

 

 

-  Do  not  run  the  generator  in  an  environment  with 
escaping  gas,  paint  vapours,  solvents  or  other 
combustible materials - RISK OF EXPLOSION!!!

 

- Do not smoke and do not use open flames near the fuel 
canisters or containers RISK OF EXPLOSION!!!

 

 

- Do not operate the generator in forest areas or similar 
without a spark arrester

 

- RISK OF FIRE!!!

 

 

- Do not operate the generator, when it is wet or damp

 

- RISK OF ELECTRIC SHOCK OR EVEN DEATH!!!

 

 

-  Before  starting  the  operation,  check  the  technical 
condition  of  the  device,  especially  guard  covers  the 
cable insulation.

 

 

- Do not touch the rotating parts during operation

 

RISK OF INJURIES OR HEALTH DAMAGE!!!

 

 

- During operation of the power generator, pay attention to 
children and animals present in its vicinity

 

 

- Do not transport and do not leave the power generator 
in closed rooms immediately after the operation

 

- RISK OF FIRE!!!

 

 

- Do not place any objects on the operating 
generator. Pay attention to any objects near 
the generator - its parts heat up to high 
temperatures during operation - RISK OF 
IGNITION!!!

 

 

-  During  operation,  and  a  long  time  after  its  inactivation, 
do  not  touch  the  exhaust  system  and  silencer  shields  - 
RISK OF BURNS!!!

 

 

-  Do  not  operate  or  stop  the  generator  under  load  - 
RISK OF DAMAGE!!! (of the generator and the connected 
receivers)

 

 

-  Do  not  adjust  the  engine  speed  by  yourself  -  RISK  OF 
ELECTRIC  SHOCK  OR  ALTERNATOR  DAMAGE!!!
(failure 
of alternator's winding or generating a high voltage).

 

 

- Do not fill the generator with non-compatible fluids, fuel 
or  with  oil  of  inadequate  quantity  and  quality  (check  oil 
level daily or every 8 hours of operation, in case of oil loss - 
refill with oil of the same parameters)

 

- RISK OF DAMAGE AND GUARANTEE LOSS!!!

 

Summary of Contents for FH 9000

Page 1: ...FH9220W FH9540TR FH9540TRA FH9540TRE FH9540 BRIGGS FV10001CRA FV10001TE FV10001TRA FV10001TRE FV10300TWE FV10300WE FV11300TWE FV11001CRA FV11001TE FV11001TRA FV11001TRE FV13000CRA FV13000TE FV13000TR...

Page 2: ...illegible or destroyed contact your Authorized Dealer of FOGO Sp z o o in order to replace them with new ones We strongly recommend carefully reading and understanding the safety rules included in ou...

Page 3: ...generator it is essential to read these instructions The buyer of the power generator must ensure that this manual is always available for its operator and that every user reads the manual before sta...

Page 4: ...Delivery unloading storage 11 5 Disposal 11 6 Operation 13 Starting 13 Stopping 17 7 Repair maintenance 19 List of maintenance operations 19 Maintenance methods 19 Faults 22 8 Maintenance 23 List of s...

Page 5: ...t breaker electric starter and the battery The optional accessories include working hour meter grounding set transport kit a hose for the exhaust system welding wires units with a welding module autom...

Page 6: ...peration The drive from the engine is transmitted through a tapered connection and threaded rod Alternator housing is made of light aluminium alloys Winding of the rotor and stator is insulated with a...

Page 7: ...of the generator Cooling in these alternators is carried out by forced air circulation in slots outside the alternator 4 6 safe 8 9 10 11 12 MARKING OF THE POWER GENERATOR 2 1 13 14 DESCRIPTION OF THE...

Page 8: ...uirements for explosion protection Do not fill the fuel tank while the engine is working RISK OF EXPLOSION Do not start the power generator in case of fuel spillage Restarting is permitted after remov...

Page 9: ...rts Damage to the power cord increases the RISK OF ELECTRIC SHOCK If you work outside enclosed rooms use extension cords intended for use outdoors Using suitable extension cords reduces the RISK OF EL...

Page 10: ...tor in conditions different than the nominal conditions Rated power is specified for specific operational conditions atmospheric pressure of 1 bar air temp of 20 C air humidity of 60 Power drop caused...

Page 11: ...rator is up to 1 2 times higher than the rated power of the heaters Sodium power of the generator is up to 5 times higher than the rated power of the bulb UPS Power of the generator up to 1 7 times la...

Page 12: ...ower generator against dust and corrosion clean the power generator from any dirt Detailed recommendations are presented in manuals provided by manufacturers of the engine alternator and other essenti...

Page 13: ...ous waste includes used objects solids and liquids other than wastewater generated in households commercial facilities unsuitable for the place and time in which they have been generated and burdensom...

Page 14: ...1 Oils shown in Table may be used if the average ambient temperature is within the indicated range For Briggs Stratton Vanguard SE SF SG SAE30 oils may be used Tab 2 Depending on the temperature for...

Page 15: ...e of 12V and a capacity of at least 18Ah built in and non built in single cylinder generators 30Ah non built in two cylinder generators 35Ah built in two cylinder generators Connecting the battery to...

Page 16: ...connection of the battery with faulty reversed polarity will automatically switch off the engine in Honda engines The green indicator in the switch indicates that the switch is turned off Remove the...

Page 17: ...tch engages with the attaching basket located placed on the engine flywheel Vigorously pull the cord If the start up fails repeat until it is successful If the starter cord is pulled by engaging clutc...

Page 18: ...il fuel mixture may overflow the piston and immobilize the engine In such cases remove the spark plug drain oil clean the combustion chamber with compressed air and change the oil VANGUARD CAUTION Whe...

Page 19: ...mum welding current only for a few minutes then it should be left to cool down see the table on the control panel therefore if the work with high welding currents triggers the thermal switch welding s...

Page 20: ...tic conditions especially at high humidity it is recommended to measure the insulation resistance of the alternator using a megohmmeter of 500 V The insulation resistance should be not less than 1 M I...

Page 21: ...er with a new one Replacing the oil filter only the power generators with VANGUARD two cylinder engines Replace the oil filter every 100 operating hours or every season Before installing the new filte...

Page 22: ...g agent and allow drying Cleaning the fuel sump MITSUBISHI engines Set the fuel valve at OFF position closed Remove the fuel sump together with the sealing O ring a fine mesh is installed above it to...

Page 23: ...load 1 The capacitance of the capacitor is too high 2 Excessive engine speed 3 Damaged excitation system 1 Check and replace if necessary 2 Report to the Servicing Department 3 Report to the Servicing...

Page 24: ...vities Engine speed control this activity must be performed by an authorized workshop service Checking the fuel system action performed in an authorised workshop MITSUBISHI FOGO DEFECTS National servi...

Page 25: ...falling very quickly sometimes even after 2 3 weeks Do not use fuel older than 1 month Store a minimum amount of fuel required For a very long storage 1 Drain the fuel from the carburettor to a suitab...

Page 26: ...n metal parts of the power generator It is also recommended for power generators equipped with other types of electrical protection Hose for exhaust system required when working indoors or on a vehicl...

Page 27: ...10 Repair log book 26 REPAIR ORDER NO RECEIPT DATE DATE OF RETURN DESCRIPTION OF FAILURE REPAIR COMMENTS...

Page 28: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Page 29: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Page 30: ...ion Type Engine No Power generator No Inspection Interval Counter indication Materials Part No Materials Part No Oil Oil Oil filter Oil filter Air filter Air filter Fuel filter Fuel filter Additional...

Page 31: ......

Page 32: ...which will be described in future versions of the manual by the services responsible for the change If you find any transcription errors or inconsistencies in the manual plese report them using the en...

Reviews: