4. Delivery, unloading, storage 

 

 
 

 
 
 

 

 
 

 

For  transport  purposes,  the  power  generator  is 
protected against the influence of weather. After 
unpacking,  remove  the  packing  materials  in  a 
way  safe  for  the  environment.  Detailed 
information  on waste  handling is  defined in the 
Regulation  of  the  Minister  of  Economy  and 
Labour  of  14  December  2013  -  Dz.U.  of  2013, 
item 21.

 

 

 
UNLOADING

 

The  recipient  of  the  power  generator  is  responsible 
for  its  unloading  and  safety.  To  unload  the  power 
generator,  observe  the  general  safety  rules  and  H&S 
regulations.

 

In particular, observe the following:

 

for  unloading  always  use  equipment  dedicated  for 

this  purpose  (crane,  forklift)  with  a  suitable  lifting 
capacity

 

all hooks must be safely attached to dedicated 

lugs - carry out unloading on a properly 
hardened surface, which is suitable to withstand 
the weight of the power generator and 
unloading equipment.

 

STORAGE

 

When  the  power  generator  is  to  be  stored  for  a 
longer period, follow the basic rules:

 

store  it  in  properly  prepared  room  (dry  and 

ventilated)

 

adequately  secure  power  generator  against 

dust and corrosion

 

clean the power generator from any dirt

 

 

Detailed  recommendations  are  presented  in 
manuals provided by manufacturers of the engine, 
alternator and other essential components.

 

 

The generator should  be handled  using  dedicated 
lugs,  which  form  also  the  frame  of  the  device. 
Observe  H&S  regulations  when  handling  the 
power generator. In case of handling heavy loads, 
it is necessary to use suitable equipment.

 

DISPOSAL

 

The  purpose  of  disposal  /  recycling 
is 
reduced use of natural 
resources and minimizing amount of 
waste. According to the Waste Act of 
11 September 2015 on

 

electrical  and  electronic  equipment  waste,  term 
"recycling"  means  a  recovery,  which  involves  re-
processing  of  substances  or  materials  contained  in 
the  waste  to  maximize  re-use  of  these  materials, 
including  minimizing  of  expenditures  for  their 
processing,  which  protects  natural  resources  used 
for their manufacture and further processing.

 

 
 
 

 
 
 

CAUTION!  Both  the  generator 
and 
materials 

used 

for 

its 

construction  and  operation  may 
cause  considerable  damage  to 
the 

environment 

when 

improperly  disposed  of.  By  re-
using  of  materials  or  other  forms 
of using old appliances, you make 
an  important  contribution  to 
protecting our environment.

 

 

11

 

Summary of Contents for FH 9000

Page 1: ...FH9220W FH9540TR FH9540TRA FH9540TRE FH9540 BRIGGS FV10001CRA FV10001TE FV10001TRA FV10001TRE FV10300TWE FV10300WE FV11300TWE FV11001CRA FV11001TE FV11001TRA FV11001TRE FV13000CRA FV13000TE FV13000TR...

Page 2: ...illegible or destroyed contact your Authorized Dealer of FOGO Sp z o o in order to replace them with new ones We strongly recommend carefully reading and understanding the safety rules included in ou...

Page 3: ...generator it is essential to read these instructions The buyer of the power generator must ensure that this manual is always available for its operator and that every user reads the manual before sta...

Page 4: ...Delivery unloading storage 11 5 Disposal 11 6 Operation 13 Starting 13 Stopping 17 7 Repair maintenance 19 List of maintenance operations 19 Maintenance methods 19 Faults 22 8 Maintenance 23 List of s...

Page 5: ...t breaker electric starter and the battery The optional accessories include working hour meter grounding set transport kit a hose for the exhaust system welding wires units with a welding module autom...

Page 6: ...peration The drive from the engine is transmitted through a tapered connection and threaded rod Alternator housing is made of light aluminium alloys Winding of the rotor and stator is insulated with a...

Page 7: ...of the generator Cooling in these alternators is carried out by forced air circulation in slots outside the alternator 4 6 safe 8 9 10 11 12 MARKING OF THE POWER GENERATOR 2 1 13 14 DESCRIPTION OF THE...

Page 8: ...uirements for explosion protection Do not fill the fuel tank while the engine is working RISK OF EXPLOSION Do not start the power generator in case of fuel spillage Restarting is permitted after remov...

Page 9: ...rts Damage to the power cord increases the RISK OF ELECTRIC SHOCK If you work outside enclosed rooms use extension cords intended for use outdoors Using suitable extension cords reduces the RISK OF EL...

Page 10: ...tor in conditions different than the nominal conditions Rated power is specified for specific operational conditions atmospheric pressure of 1 bar air temp of 20 C air humidity of 60 Power drop caused...

Page 11: ...rator is up to 1 2 times higher than the rated power of the heaters Sodium power of the generator is up to 5 times higher than the rated power of the bulb UPS Power of the generator up to 1 7 times la...

Page 12: ...ower generator against dust and corrosion clean the power generator from any dirt Detailed recommendations are presented in manuals provided by manufacturers of the engine alternator and other essenti...

Page 13: ...ous waste includes used objects solids and liquids other than wastewater generated in households commercial facilities unsuitable for the place and time in which they have been generated and burdensom...

Page 14: ...1 Oils shown in Table may be used if the average ambient temperature is within the indicated range For Briggs Stratton Vanguard SE SF SG SAE30 oils may be used Tab 2 Depending on the temperature for...

Page 15: ...e of 12V and a capacity of at least 18Ah built in and non built in single cylinder generators 30Ah non built in two cylinder generators 35Ah built in two cylinder generators Connecting the battery to...

Page 16: ...connection of the battery with faulty reversed polarity will automatically switch off the engine in Honda engines The green indicator in the switch indicates that the switch is turned off Remove the...

Page 17: ...tch engages with the attaching basket located placed on the engine flywheel Vigorously pull the cord If the start up fails repeat until it is successful If the starter cord is pulled by engaging clutc...

Page 18: ...il fuel mixture may overflow the piston and immobilize the engine In such cases remove the spark plug drain oil clean the combustion chamber with compressed air and change the oil VANGUARD CAUTION Whe...

Page 19: ...mum welding current only for a few minutes then it should be left to cool down see the table on the control panel therefore if the work with high welding currents triggers the thermal switch welding s...

Page 20: ...tic conditions especially at high humidity it is recommended to measure the insulation resistance of the alternator using a megohmmeter of 500 V The insulation resistance should be not less than 1 M I...

Page 21: ...er with a new one Replacing the oil filter only the power generators with VANGUARD two cylinder engines Replace the oil filter every 100 operating hours or every season Before installing the new filte...

Page 22: ...g agent and allow drying Cleaning the fuel sump MITSUBISHI engines Set the fuel valve at OFF position closed Remove the fuel sump together with the sealing O ring a fine mesh is installed above it to...

Page 23: ...load 1 The capacitance of the capacitor is too high 2 Excessive engine speed 3 Damaged excitation system 1 Check and replace if necessary 2 Report to the Servicing Department 3 Report to the Servicing...

Page 24: ...vities Engine speed control this activity must be performed by an authorized workshop service Checking the fuel system action performed in an authorised workshop MITSUBISHI FOGO DEFECTS National servi...

Page 25: ...falling very quickly sometimes even after 2 3 weeks Do not use fuel older than 1 month Store a minimum amount of fuel required For a very long storage 1 Drain the fuel from the carburettor to a suitab...

Page 26: ...n metal parts of the power generator It is also recommended for power generators equipped with other types of electrical protection Hose for exhaust system required when working indoors or on a vehicl...

Page 27: ...10 Repair log book 26 REPAIR ORDER NO RECEIPT DATE DATE OF RETURN DESCRIPTION OF FAILURE REPAIR COMMENTS...

Page 28: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Page 29: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Page 30: ...ion Type Engine No Power generator No Inspection Interval Counter indication Materials Part No Materials Part No Oil Oil Oil filter Oil filter Air filter Air filter Fuel filter Fuel filter Additional...

Page 31: ......

Page 32: ...which will be described in future versions of the manual by the services responsible for the change If you find any transcription errors or inconsistencies in the manual plese report them using the en...

Reviews: