background image

9

Cube x2

This assembly comprises two support bases. One is to be attached to the free standing fire unit, as a Cube support base;
and the second one holding the glass is to be attached to the assembly.

To install the glass onto the base, insert the metal supports into their corresponding positions using the provided screws
and washers to secure the assembly. Then place the glass on the top of the metal brackets and level with the base.

Table

This base can be mounted in three different positions:

Position A – Left hand side
Position B – Central
Position C – Right hand side

To mount the base, set it on the desired location and then place the unit in the selected position. Place the free standing
fire unit on the supporting base, carefully matching the screw holes on the bottom relative to the intended position (K and
L) with the guide pins (J) on the supporting base.

Position A

Position B

Position C

Square

Round

Spider

Cube

Summary of Contents for Versatile H600

Page 1: ...Starting combustion 5 10 Controls 5 11 Lighting the free standing fire 5 12 Managing the free standing fire 6 13 Cleaning 6 14 Maintenance 7 15 Troubleshooting 10 16 Warranty 10 HIGH TEMPERATURE HEATI...

Page 2: ...amp or green wood It is the only unit that prevents the emission of harmful substances during burning Damp wood can damage and corrode the unit originating rust within a short period of time You shoul...

Page 3: ...imney has been out of operation for a long time you should have it checked by an expert The chimney must have enough height to allow for fume exhaustion at 12 20 Pascal minimum The fume exhaustion can...

Page 4: ...cialists Please keep in mind the following considerations The door of the appliance must be closed at all times irrespective of the appliance s operating status on off The household must allow for a p...

Page 5: ...ich upon condensation causes the build up of tar onto the combustion chamber chimney and glass panel A tar build up not only is unpleasant to the eye but it also requires regular chimney cleaning to p...

Page 6: ...nd convection heat output Very high wood consumption Fully open the aeration control to create a fast burning flame This setting should only be used to light the unit Once the appliance is hot you sho...

Page 7: ...information on the requirements of the Clean Air Act can be found here http smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation...

Page 8: ...oxidation The same caution applies to the sealing rope and other components which may be damaged if in contact with these products 4 Allow the cleaner to work 5 Wipe off tar deposits using a slightly...

Page 9: ...a year To do this remove the smoke damper Fig 1 from the unit To remove the smoke damper follow the steps below 1 Open the door to remove the smoke deflector Fig 2 To do this place a hand on the smok...

Page 10: ...lly hold the replacement glass leaning the upper end against the top part of the door the bottom end will slide into place 3 Slide the glass downwards towards the bottom of the door to fit the upper e...

Page 11: ...hen place the glass on the top of the metal brackets and level with the base Table This base can be mounted in three different positions Position A Left hand side Position B Central Position C Right h...

Page 12: ...ype of fuel used and the handling of the unit are beyond FOGO MONTANHA s control so parts in direct contact with the flame are not covered by this warranty for instance glass sealing bundles and vermi...

Page 13: ...S600 UK V1 2014...

Reviews: