Fogg Company
Microb-Blaster
®
Air Sanitizer
Page 12
MAINTENANCE
Changing the Lamps
Microb-Blaster
®
Air Sanitizer 2400
1. Disconnect the power and allow the unit to cool.
2. Open the top of the unit by unscrewing the four screws.
3. Remove the top cover.
4. Disconnect the Lamp:
a. Lift lamp slightly out of its pocket,
b. Firmly grasp the lamp,
c. Pull plug from the top of the lamp.
DO NOT TWIST!!!
5. Lift the old lamps out.
6. Gently slide the new lamps into the pockets.
Location of Screws