![Foerster 6.461.21 Operating Instructions Manual Download Page 28](http://html1.mh-extra.com/html/foerster/6-461-21/6-461-21_operating-instructions-manual_2314653028.webp)
SENSOR SYSTEM Ro 35 L
2.6 Environmental conditions
DESCRIPTION
2-16
6.461.21 - 2008/06
2.6 Environmental
conditions
Operation
Temperature range
sensor
rotating
system
+5° C to +80° C
+5° C to +45° C
Relative humidity
sensor
rotating
system
95 %, casually condensation permissible
85 %, condensation not permissible
Degree of protection
sensor
rotating
system
EN (60 529)
IP 65
IP 43
Storage and transport
Storage, transport and handling may be carried out in original packaging
only. The packages must be protected from moisture.
Observe instructions on the packaging (e.g. fragile, store in a dry place,
this way up, etc.)
Storage conditions
storage in unopened original packaging
in closed rooms
temperature range -20° C to +70° C
max. relative humidity 95 %, condensation not permissible
maximum storage duration approx. 12 months (extension possible after
intermediate check by FOERSTER employee)
Emissions
The A-weighted sound pressure level at intervals of 1 m from the ma-
chine's surface and at 1.60 m height is for maximum rotational speed
9,000 rpm on exit side
outside testing line: without material 91 dB(A), with material 88 dB(A)
Inside the testing line the values are smaller (dependent on the installa-
tion). On the operator's workstations the values are smaller in the case of
greater distances.