Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.
FIREFRONT - Any dust accumulating in the firefront may be removed using a vacuum cleaner or dry cloth. Heavy stains may be

removed by using a damp cloth and mild household detergent. Brass parts of the firefront may be cleaned using a suitable brass

cleaner. Replace the front centrally against the fire after cleaning. Do not use a damp cloth to clean cast iron fronts.
PAINTED AREAS - These can be cleaned using a dry cloth.
COALS AND CERAMICS - Remove the firefront and place to one side. Remove the ceramic components. Gently clean in the

open air. Be careful not to create dust from the coals. Where necessary replace damaged components with genuine spares. Seal

scrap components in plastic bags and dispose of at proper refuse sites as directed.
Re-fit the ceramics carefully by referring to the relevant section of these instructions.

Handset - Remove cover from rear of handset and insert 1 x ‘PP3’ (9 volt) battery - Replace cover.

Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.

Appliance - Ensure appliance is off and cool. Remove cover from top of receiver box. 

The cover is protected by reflective foil, and located towards the right hand side, underneath the burner unit. Insert 4 x ‘AA’ (1.5

volt) batteries - Replace cover.

9.0 CLEANING

8

'

2013 Focal Point Fires plc.

GB IE

10.0 REPLACING THE BATTERIES 

(REMOTE CONTROL VERSIONS)

11.0 LIST OF REPLACEMENT PARTS

Item

Part number

Pack of 16 coals

F550038

Pack of 16 pebbles

F550050

Pack of 9 ceramic logs

F550084

Front ceramic strip - coal

F780008

Front ceramic strip - pebble

F780017

Front ceramic strip - Log

F780050

Ceramic combustion matrix - coal

F780007

Ceramic combustion matrix - pebble

F780016

Ceramic combustion matrix - Log

F780051

Oxypilot 9081 - All models

F730006

Gas valve - manual control models

F730085

Gas valve - remote control models

F730011

Injector - stereo 76 - manual control models

F730091

Injector - stereo 81 - Remote control models

F730046

Burner assembly - complete - manual control

TRAYEXCELC

Burner assembly - complete - remote control

TRAY017

Summary of Contents for HANNINGTON

Page 1: ...oint Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INSTALL REP...

Page 2: ...onsiders all surfaces as working surfaces with the exception of the control knob and ash pan door As with any gas fire a fire guard complying with BS 8423 must be used in presence of pets children and...

Page 3: ...e with an inset Decorative Fuel Effect Fire BS5871 part 3 contains further details The fireplace opening should be inspected and repairs made where nec essary Any chair brick may be left in place The...

Page 4: ...to unpack or install this appliance Remove the box containing the firefront and the bag containing the coals Remove the cardboard packing pieces and any bags contain ing other fittings or parts Remove...

Page 5: ...e main burner control shown in figure 3 on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on right hand side of control valve slightly left towards the ignition pos...

Page 6: ...to the back of the gas control valve may also have worked loose during installation simply tighten to remedy if this is the case If pilot disturbance is not the cause then the ODS safety system may be...

Page 7: ...with smoke pellet for correct operation 7 Strip off the burner pipes and clean thoroughly 8 Clean out the injector and pilot assembly DO NOT attempt to dismantle the pilot unit 9 Ensure the injector...

Page 8: ...rthing to metal work reset gap correctly Blocked pilot clean out internally Pilot lights but then goes out Severe restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Hol...

Page 9: ...The fire is only suitable for use with the gas type for which it is supplied This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions occur...

Page 10: ...lowing the instructions given in the Installation section The Installation instructions carry full servicing details for the use of the installer If debris from the flue or other foreign matter is fou...

Page 11: ...ontrol valve slightly left towards the ignition position until reaching the stop press down and hold for 5 seconds only pilot gas is flowing Continue pressing down the knob while turning further to th...

Page 12: ...should sit snugly behind the back edge of the burner rails as shown in figure 7 Do not fit the matrix on top of the burner rails 2 Position the front coal strip as shown in figure 8 The rear edge of...

Page 13: ...of the fuel matrix 6 Finally take the two remaining coals and place at the back of the fuel matrix in the centre as shown in figure 12 Adding these coals should complete the appearance of the fuel be...

Page 14: ...take another two pebbles and place behind the second row of pebbles next to each other in the centre of the fuel bed as shown in fig ure 16 The pebbles may be orientated as desired to achieve a reali...

Page 15: ...al ly as shown in figure 21 ensuring correct orientation The base of this log must rest securely on the front log strip Take one of the smaller logs numbered 14 and position in between the two vertica...

Page 16: ...f handset and insert 1 x PP3 9 volt battery Replace cover Before carrying out any of the following operations ensure that the fire is OFF and completely cold Appliance Ensure appliance is off and cool...

Page 17: ...nditions for your product have been met then please submit the following information for the attention of the 3G Service Department to the address below Alternatively you can email or fax Please note...

Reviews: