background image

The pilot is visible through the left hand side of ceramic fuel matrix. When cold, the coals or peb-

bles may be rotated for good viewing. The fire features a ‘twin spark’ ignition system to aid light-

ing, Push the control knob in fully and turn anti-clockwise through both of the SPARK positions,

keeping fully depressed, hold there for a few seconds. If the fire has not been used for some time,

hold the knob in this position for longer, to allow any air in the pipes to be purged.

Ensure the pilot has lit. If not, return the knob clockwise, and repeat. When the pilot lights after

one of the two sparks, keep the knob depressed in the nine o’clock position for approximately

ten seconds. Now release the knob and the pilot should stay alight. If the pilot is extinguished

during use, wait three minutes before repeating the ignition procedure. 

To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clock-

wise to the high position. The main burner should light after a few seconds. To decrease the set-

ting to LOW, push the knob in slightly and turn the control knob clockwise to the low setting.

To turn to the pilot only position from the HIGH or LOW positions, press the control knob in,

and return to the nine o’clock position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release.

The pilot is visible through the left hand side of ceramic fuel matrix. When cold, the coals or pebbles may be rotated for good

viewing.  Turn the main burner control (shown in figure 4 on left hand side of control valve) knob fully anti-clockwise. 

Turn ignition knob (shown on right hand side of control valve) slightly left towards the ignition position until reaching the stop,

press down and hold for 5 seconds (only pilot gas is flowing).

Continue pressing down the knob while turning further to the left to activate

the piezo spark, continue to hold the knob down for a further 10 seconds after

the pilot has been lit. If the pilot does not light repeat the previous steps. 

Upon lighting and after the further 10 seconds, release the knob and turn fur-

ther to the left to the ON position. The main burner will light and be con-

trolled in accordance with the main burner control  knob setting. Adjust the

main burner control knob to the desired setting. 

If the pilot is extinguished during use of the fire, you MUST wait ten minutes

before repeating the ignition procedure.

To turn the main burner OFF whilst keeping the pilot flame lit, turn the igni-

tion control knob to the pilot position then only the pilot will remain lit.

To shut the fire off completely, press the ignition control  knob down and con-

tinue turning to the right from the pilot position to the OFF position.

A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled suf-

ficiently to allow the magnetic valve unit to reset itself.

The remote control unit allows operation of the main burner setting between maximum and

pilot only setting. It does not permanently turn the pilot on or off. 

The remote control handset incorporates an inbuilt safety feature to prevent the main burner

being activated or turned up accidentally. It is necessary to press buttons 1 and 2 (see figure 5)

simultaneously to turn the fire up. 

To turn the fire down press button 3 only.

6.0 OPERATING THE FIRE 

(MANUAL CONTROL MODELS)

 

    FIN:

A

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

Figure 3

GB IE

3

'

2013 Focal Point Fires plc.

6.1 OPERATING THE FIRE 

(REMOTE CONTROL MODELS)

 

    FIN:

A

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

1

2

3

 

    FIN:

A

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: No reference

1

 

Figure 4

Figure 5

Summary of Contents for HANNINGTON

Page 1: ...oint Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INSTALL REP...

Page 2: ...onsiders all surfaces as working surfaces with the exception of the control knob and ash pan door As with any gas fire a fire guard complying with BS 8423 must be used in presence of pets children and...

Page 3: ...e with an inset Decorative Fuel Effect Fire BS5871 part 3 contains further details The fireplace opening should be inspected and repairs made where nec essary Any chair brick may be left in place The...

Page 4: ...to unpack or install this appliance Remove the box containing the firefront and the bag containing the coals Remove the cardboard packing pieces and any bags contain ing other fittings or parts Remove...

Page 5: ...e main burner control shown in figure 3 on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on right hand side of control valve slightly left towards the ignition pos...

Page 6: ...to the back of the gas control valve may also have worked loose during installation simply tighten to remedy if this is the case If pilot disturbance is not the cause then the ODS safety system may be...

Page 7: ...with smoke pellet for correct operation 7 Strip off the burner pipes and clean thoroughly 8 Clean out the injector and pilot assembly DO NOT attempt to dismantle the pilot unit 9 Ensure the injector...

Page 8: ...rthing to metal work reset gap correctly Blocked pilot clean out internally Pilot lights but then goes out Severe restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Hol...

Page 9: ...The fire is only suitable for use with the gas type for which it is supplied This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions occur...

Page 10: ...lowing the instructions given in the Installation section The Installation instructions carry full servicing details for the use of the installer If debris from the flue or other foreign matter is fou...

Page 11: ...ontrol valve slightly left towards the ignition position until reaching the stop press down and hold for 5 seconds only pilot gas is flowing Continue pressing down the knob while turning further to th...

Page 12: ...should sit snugly behind the back edge of the burner rails as shown in figure 7 Do not fit the matrix on top of the burner rails 2 Position the front coal strip as shown in figure 8 The rear edge of...

Page 13: ...of the fuel matrix 6 Finally take the two remaining coals and place at the back of the fuel matrix in the centre as shown in figure 12 Adding these coals should complete the appearance of the fuel be...

Page 14: ...take another two pebbles and place behind the second row of pebbles next to each other in the centre of the fuel bed as shown in fig ure 16 The pebbles may be orientated as desired to achieve a reali...

Page 15: ...al ly as shown in figure 21 ensuring correct orientation The base of this log must rest securely on the front log strip Take one of the smaller logs numbered 14 and position in between the two vertica...

Page 16: ...f handset and insert 1 x PP3 9 volt battery Replace cover Before carrying out any of the following operations ensure that the fire is OFF and completely cold Appliance Ensure appliance is off and cool...

Page 17: ...nditions for your product have been met then please submit the following information for the attention of the 3G Service Department to the address below Alternatively you can email or fax Please note...

Reviews: