background image

5.0 COMPONENT CHECKLIST - CONTINUED

4

©

2014 Focal Point Fires plc.

GB IE

7. Logs

8. Pebbles Dependent On Model

9. Fuel Bed Holder

10. Remote Control

6.0 SITE REQUIREMENTS

It should be noted that the appliance creates warm convected air currents. These currents move heat from the room

surroundings to, and up the wall surfaces adjacent to the heater. 

Installing the heater next to these types of wall coverings or operating the heater where impurities in the air, (such as tobacco

smoke) exist, may slightly discolour wall finishing.

If the appliance is to be mounted on a dry lined or timber framed construction then the integrity and ability of the wall to

carry the weight of the appliance must be confirmed. It is important in these circumstances that any vapour barrier and/or

structural members of the house frame are not damaged. 

If you are unsure of the ability of the wall to carry the weight and/or which type of wall fixing to use, you should take

professional advice and obtain the correct fixings. Alternatively, find a more suitable wall location.

DO NOT

• mount on a ceiling or floor

• recess any part of the appliance into the wall, or run the supply cable under carpets

• site any electrical equipment e.g. plasma screen TV sets etc, on the wall below the appliance.

• site in a position where curtains or drapes could cover the appliance, or other soft materials could cover e.g. below a coat   

rack

• site behind an opening door where mechanical impact/damage could occur

• site where the supply cable would become a trip hazard

• sit, stand or forcefully pull on the appliance

• obstruct, cover or force items into the openings

• use the heater to dry clothes

• site/use in an outdoor location(s)

It is important that the following clearances are maintained from the appliance to combustible materials. These clearances are

dependent on the mounting location as defined below:

• The minimum distance from the top of the appliance to a ceiling is 300mm

• The minimum distance from the bottom of the appliance to the floor is 200mm

• The minimum distance to the sides of the appliance is 100mm

• The minimum distance to the front of the appliance is 500mm

7.0 CLEARANCES TO COMBUSTIBLE MATERIALS

Summary of Contents for EF11-36 PASADENA LIMOUSIN

Page 1: ...is owned by Focal Point Fires plc You are not permitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc 1 Revision A 09 14 GB IE Focal Point Fires plc...

Page 2: ...have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Cleaning and user maintenance shall not be made by children without supervi...

Page 3: ...kg Supply Voltage 230V AC 50Hz Fuse Rating 13 Amp Heating Elements 1500W Lighting LED This fire is fitted with LED s Light Emitting Diode in place of conventional bulbs LED s generate the same light l...

Page 4: ...correct fixings Alternatively find a more suitable wall location DO NOT mount on a ceiling or floor recess any part of the appliance into the wall or run the supply cable under carpets site any electr...

Page 5: ...wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings In this situation any additional f...

Page 6: ...ired mounting location using the Mounting Bracket as a template 5 With an electric drill not included on its low setting drill 5 16 inch diameter holes to at least 1 inch deep on the marked points NOT...

Page 7: ...secure it to the Mounting Bracket by refitting the two small screws which were removed in step 2 As shown NOTE We provided the optional pebbles for the fuel bed holder To change the fuel bed follow t...

Page 8: ...that you use two people at this stage to prevent to the Glass Fascia or the Firebox 13 Secure the Glass Fascia to the Firebox by fastening two M4 x 8 mm Screws 1 on both sides As shown 1 Unpack the un...

Page 9: ...Deflector 9 2014 Focal Point Fires plc 5 Ask for assistance to position the Firebox onto Table Top Support so that the top hooks of the Table Top Support properly fit into the bottom slots and the bac...

Page 10: ...On the top right side plate of the Electric Fireplace is the control panel This panel contains the buttons to properly operate the electric fireplace The buttons on the control panel on the side of th...

Page 11: ...and flame effect Pressing the flames control button 2 once turns flames on and lights the ember bed Pressing the flames control button 2 again will cycle through different colours of the ember bed Th...

Page 12: ...ol panel heater button for 10 seconds the ember bed will flash 6 times and the heat function will be restored Manual ON OFF switch There is a manual ON OFF switch is located on the right hand side of...

Page 13: ...fires purchased the 3 year guarantee commences from the date of purchase provided that the following 3 terms and conditions are adhered to For all electric fires purchased the 3 year guarantee commen...

Reviews: