background image

INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

MULTIFLUE/INSET GAS FIRE

Please  note  :  Except  where  otherwise  stated,  all  rights,  including

copyright in the text, images and layout of this booklet is owned by

Focal Point Fires plc.  You are not permitted to copy or adapt any of

the content without the prior written permission of Focal Point Fires

plc. 

1

Revision F - 06/14

© 2014 Focal Point Fires plc.

GB IE

Focal Point Fires plc.

Christchurch, Dorset BH23 2BT

Tel: 01202 499330     

Fax: 01202 499326

www.focalpointfires.co.uk

e : [email protected]

IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE

MODELS COVERED BY THESE INSTRUCTIONS

BLENHEIM MULTIFLUE

**

LULWORTH MULTIFLUE

† †

EXCELSIOR MULTIFLUE

VOGUE

AURA MULTIFLUE

FINSBURY MULTIFLUE

** 

SOHO MULTIFLUE

†  

BI-FLAME

*

HORIZON MULIFLUE

† †

LANGHAM MULTIFLUE

† †

*   AVAILABLE WITH MANUAL CONTROL ONLY

†   AVAILABLE WITH MANUAL OR SLIDE CONTROL

† † AVAILABLE WITH MANUAL OR REMOTE CONTROL

**  AVAILABLE WITH MANUAL, SLIDE CONTROL OR REMOTE CONTROL

MODEL SHOWN: BLENHEIM MULTIFLUE

Questions or problems with your appliance?

Don’t take it back to the store

just give us a call on 

01202 588601

we’re here to help

lines open between 9am and 5pm, Monday to Friday

Summary of Contents for Aura Multiflue

Page 1: ...326 www focalpointfires co uk e sales focalpointfires co uk INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INSTALL REPAIR OR SERVICETHIS APPLIANCE MODELS COVERED BY THESE INSTRUCTIONS BLENHEIM M...

Page 2: ...ion and use of this appliance This appliance is free from any asbestos material Refractories and fuel bed are constructed from ceramic fibre Remote control models These appliances features a battery o...

Page 3: ...not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not...

Page 4: ...place opening providing the forward projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decora...

Page 5: ...ation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any...

Page 6: ...ontrol position marking sticker on the trim next to the control knob as shown in figure 16 Before installing the fire check the flue using a smoke pellet All of the smoke should travel up the flue and...

Page 7: ...e tensioner nuts to pull the appliance tightly against the fireplace opening Visually inspect the seal and reseat if necessary Do not cut off excess cable Surplus cable must not be cut off as it will...

Page 8: ...for some time hold the knob in this position for longer to allow any air in the pipes to be purged Continue turning anti clockwise through the spark clicks to the nine o clock position ensuring the pi...

Page 9: ...own and the pilot lit with a taper Light the fire on the HIGH setting To commission the appliance the operating pressure must be in accordance with the figures stated in section 2 0 of these instructi...

Page 10: ...this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in the instal...

Page 11: ...n the rear of the valve and the two securing screws and lifting away Remove the tubing nut from the valve end of the pilot pipe and blow through to dislodge any debris Clean the pilot assembly with a...

Page 12: ...Blocked pilot clean out Excessive drafts in the room Excessive flue pull Fire is too close to an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will no...

Page 13: ...installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if...

Page 14: ...ng Push the control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the...

Page 15: ...porates an inbuilt safety feature to prevent the main burner being activated or turned up accidentally It is necessary to press button 1 and 2 see figure 5 simultaneously to turn the fire up To turn t...

Page 16: ...sides as shown Place the rear row of four coals making sure that the flat sides are firmly against the brick panel and side cheeks as shown The coals must not be crammed together or inserted into the...

Page 17: ...ith the pebbles supplied when assembled according to the instructions Never add to the fifteen pebbles or change them for a different type Never throw rubbish or other matter onto the fuel bed Due to...

Page 18: ...p cloth and mild household detergent Brass parts of the firefront may be cleaned using a suitable brass cleaner Replace the front centrally against the fire after cleaning Do not use a damp cloth to c...

Page 19: ...control models F730057 Gas valve Manual control models F730085 Gas valve Remote control models F730011 Gas valve Slide control models F730067 Injector Stereo 78 Manual Slide control models F730062 In...

Page 20: ...als pebbles the matrix front strips side cheeks rear panels and tapered rear panels are not covered by the 3 year guarantee For all Electric fires purchased the 3 year guarantee commences from the dat...