background image

Close all doors and windows to the room containing the appliance. Let the fire run on HIGH for five minutes. Take a smoke

match, light it, and using a smoke match tube, hold it at the top edge of the fire opening, 25mm down and 25mm in. Starting 50mm in

from either side, run the smoke match across the opening. 

All the smoke should be drawn away up the flue. Any smoke returning into the room indicates that spillage is occurring. If the initial

spillage test fails, run the fire for a further 10 minutes and repeat the test. 

When the test has been completed satisfactorily, repeat with any extractor fans in the premises running on the highest setting, and any

communicating doors open. Finally, repeat with all doors open.

DO NOT allow the fire to be used until the test is satisfactorily passed.

All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire. After commissioning

the appliance, the customer should be instructed on the safe use of the appliance and the need for regular servicing. Frequency of serv-

ice depends on usage, but MUST be carried out at least once annually. Advise that cleaning of the fire may be achieved when the fire is

cold using a damp cloth and mild detergent on most surfaces.

Scratched and other superficial damage to the matt black paintwork of the appliance can be covered with matching heatproof spray. Use

only the manufacturers’ recommended spray paint. Paint only when the fire is OFF and cold. Always mask off the surrounding area to

prevent contamination with overspray. Ventilate the room during the use of the spray. DO NOT attempt to wash the coals or ceramics

with water.

Advise that the fire will emit a “newness” smell for a time after initial commissioning and that extra ventilation may be needed during

this time. Advise that the fire is fitted with a spillage safety device (O.D.S.). If the fire shuts down, this system may be in operation. If

spillage is suspected, SWITCH APPLIANCE OFF and call in the installer to investigate any problems.

Isolate the fire from the gas supply. Ensure that the fire is fully cold before attempting service. A suggested procedure for servicing is

detailed below.

10

© 2014 Focal Point Fires plc.

16.7 TESTING FOR SPILLAGE

Match

Crimp

Tube

Figure 17 : Cross section of smoke match tube

Make a smoke match tube from 10mm diameter

tube. Seal off one end and crimp the tube to prevent

the smoke match from sliding down inside.

Spillage test - Figure 18

A.  25mm  down  from  top  of

opening

B. 25mm in from front of open-

ing.

C.  Disregard  outer  50mm

either side of fireplace opening

C

C

B

A

Fireplace Opening

Smoke Match

In Tube

Figure 19

GB IE

16.8 BRIEFING THE CUSTOMER

17.0 SERVICING

1. Lay out the dust sheet and tools.
2. Carefully remove the ceramic components.
3. Remove the firefront fret or the combined frame and firefront (dependant on model).
4. Disconnect the gas supply, and remove the burner securing screws (see figure 10 and refer to section 17.2)
5. Remove the burner tray.
6. Remove firebox as described in section 17.5.
7. Check the fireplace opening for rubble accumulation and remove. If debris is excessive, initiate remedial work on the flue.
8. Check the flue with smoke pellet for correct operation.
9. Refit firebox using new seals where necessary.
10. Strip off the burner pipes and clean thoroughly.
11. Clean out the injector, pilot assembly and burner tube. DO NOT attempt to remove the pilot injector.
12. Re-assemble and re-fit the burner tray.
13. Turn on the gas supply, and leak test.
14. Refit the decorative casting and ceramics.
15. Check any purpose provided ventilation is un-obstructed.
16. Light the fire and test for spillage.
17. Check the operating pressure (see section 16.5) and safe operation of the appliance.

For specific servicing instructions, see the relevant sections.

Summary of Contents for Aura Multiflue

Page 1: ...326 www focalpointfires co uk e sales focalpointfires co uk INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INSTALL REPAIR OR SERVICETHIS APPLIANCE MODELS COVERED BY THESE INSTRUCTIONS BLENHEIM M...

Page 2: ...ion and use of this appliance This appliance is free from any asbestos material Refractories and fuel bed are constructed from ceramic fibre Remote control models These appliances features a battery o...

Page 3: ...not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not...

Page 4: ...place opening providing the forward projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decora...

Page 5: ...ation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any...

Page 6: ...ontrol position marking sticker on the trim next to the control knob as shown in figure 16 Before installing the fire check the flue using a smoke pellet All of the smoke should travel up the flue and...

Page 7: ...e tensioner nuts to pull the appliance tightly against the fireplace opening Visually inspect the seal and reseat if necessary Do not cut off excess cable Surplus cable must not be cut off as it will...

Page 8: ...for some time hold the knob in this position for longer to allow any air in the pipes to be purged Continue turning anti clockwise through the spark clicks to the nine o clock position ensuring the pi...

Page 9: ...own and the pilot lit with a taper Light the fire on the HIGH setting To commission the appliance the operating pressure must be in accordance with the figures stated in section 2 0 of these instructi...

Page 10: ...this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in the instal...

Page 11: ...n the rear of the valve and the two securing screws and lifting away Remove the tubing nut from the valve end of the pilot pipe and blow through to dislodge any debris Clean the pilot assembly with a...

Page 12: ...Blocked pilot clean out Excessive drafts in the room Excessive flue pull Fire is too close to an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will no...

Page 13: ...installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if...

Page 14: ...ng Push the control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the...

Page 15: ...porates an inbuilt safety feature to prevent the main burner being activated or turned up accidentally It is necessary to press button 1 and 2 see figure 5 simultaneously to turn the fire up To turn t...

Page 16: ...sides as shown Place the rear row of four coals making sure that the flat sides are firmly against the brick panel and side cheeks as shown The coals must not be crammed together or inserted into the...

Page 17: ...ith the pebbles supplied when assembled according to the instructions Never add to the fifteen pebbles or change them for a different type Never throw rubbish or other matter onto the fuel bed Due to...

Page 18: ...p cloth and mild household detergent Brass parts of the firefront may be cleaned using a suitable brass cleaner Replace the front centrally against the fire after cleaning Do not use a damp cloth to c...

Page 19: ...control models F730057 Gas valve Manual control models F730085 Gas valve Remote control models F730011 Gas valve Slide control models F730067 Injector Stereo 78 Manual Slide control models F730062 In...

Page 20: ...als pebbles the matrix front strips side cheeks rear panels and tapered rear panels are not covered by the 3 year guarantee For all Electric fires purchased the 3 year guarantee commences from the dat...

Reviews: