FUEL BED LAYOUT - ccontinued
Place the front row of six pebbles on to the matrix. Ensure the pebbles are firmly
against the side cheeks as shown in the photograph. If necessary, pull the peb-
bles forward slightly to ensure their rear edges do not overhang the flame ports.
The pebbles MUST NOT be allowed to enter the flame ports. If in any doubt pull
the pebbles as far forward as possible.
The middle row of pebbles are fixed and cannot be moved. Place the rear row of
four pebbles, making sure that the flat sides are firmly against the brick panel and
side cheeks as shown.
Note: TThe ppebbles m
must nnot bbe ccrammed ttogether, oor iinserted iinto tthe hholes iin
the m
matrix. A
A w
well llaid oout, ggenerously sspaced ppebble llayout w
will ggive tthe bbest
results.
The fire is designed to operate correctly with the coals supplied when assembled according to the instructions. Never add to the ten pebbles,
or change them for a different type. Never throw rubbish or other matter onto the coal bed.
FLUE SSPILLAGE M
MONITORING SSYSTEM
This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no apparent reason then several reasons may
be suspected. If a door or window has been opened creating a draught, then pilot disturbance could be the problem, and removal of the
draught should resolve this. The fire can then be re-lit in accordance with the previous section. A grommet seal may also be missing from the
firebox causing abnormal draught to shut down the pilot. Call your installer to check seals are properly fitted.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, call in your installer to check
the flue and ventilation and carry out any remedial work required. DO NOT allow the appliance to be used until the flue system is passed as
safe.
CLEANING
Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.
Debris that may form on the fuelbed should be periodically removed by a competent person. Large deposits could indicate deterioration of
the flue. This should be repaired by a competent person, and the fire serviced before further use.
STAINLESS STEEL AREAS - These parts may be cleaned using an appropriate metal polish. Clean only in the direction of the grain.
Alternatively, a small amount of baby oil applied in the direction of the grain, with a soft, lint free cloth.
Another effective way to restore the 'as new' look to the stainless steel parts, is use of a proprietary car interior cleaning agent such as 'Cockpit
shine'. This should be sprayed directly on to the metal and then wiped off with a clean lint free cloth.
PAINTED AREAS - These can be cleaned using a dry cloth.
SERVICING
The fire and flue should be checked on an annual basis to ensure all of the product of combustion are entering the flue and that there is no
excessive build up of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must
be carried out by a competent person, such as a CORGI registered installer.
Cleaning of the coals/pebbles may be carried out by following the instructions given in the Installation section. The Installation instructions
carry full servicing details for the use of the installer.
If debris from the flue or other foreign matter is found on the fire it may indicate a need for servicing. Do not use the fire until the source of
the debris has been found and rectified.
Air vents (where fitted) should be checked periodically to ensure they are free from obstruction.
SHORTLIST OF SPARES
PART N
NO.
ITEM
CE/FT003033/0
Pack of 10 pebbles
CE/FT003005/0
Ceramic combustion matrix
FB/004050/0
Ceramic brick panel set (Side cheeks and rear panel)
FR/F820074
‘Lulworth’ decorative frame
TRAY001LPG
Replacement burner unit
3
6.0
7.0
8.0
9.0
10.0
As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications
without prior notice.
DO005830/0