Place the front row of six pebbles on to the matrix. Ensure the pebbles are firmly
against the side cheeks as shown in the photograph. If necessary, pull the peb-
bles forward slightly to ensure their rear edges do not overhang the flame ports.
The pebbles MUST NOT be allowed to enter the flame ports. If in any doubt pull
the pebbles as far forward as possible.

The middle row of pebbles are fixed and cannot be moved. Place the rear row of
four pebbles, making sure that the flat sides are firmly against the brick panel and
side cheeks as shown.

Note: TThe ppebbles m

must nnot bbe ccrammed ttogether, oor iinserted iinto tthe hholes iin

the m

matrix. A

A w

well llaid oout,  ggenerously sspaced ppebble llayout w

will ggive tthe bbest

results.

The fire is designed to operate correctly with the coals supplied when assembled according to the instructions. Never add to the ten pebbles,
or change them for a different type. Never throw rubbish or other matter onto the coal bed.

FLUE SSPILLAGE M

MONITORING SSYSTEM

This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no apparent reason then several reasons may
be suspected. If a door or window has been opened creating a draught, then pilot disturbance could be the problem, and removal of the
draught should resolve this. The fire can then be re-lit in accordance with the previous section. A grommet seal may also be missing from the
firebox causing abnormal draught to shut down the pilot. Call your installer to check seals are properly fitted.

If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, call in your installer to check
the flue and ventilation and carry out any remedial work required. DO NOT allow the appliance to be used until the flue system is passed as
safe.

CLEANING

Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.

Debris that may form on the fuelbed should be periodically removed by a competent person. Large deposits could indicate deterioration of
the flue. This should be repaired by a competent person, and the fire serviced before  further use.

STAINLESS STEEL AREAS - These parts may be cleaned using an appropriate metal polish. Clean only in the direction of the grain.
Alternatively, a small amount of baby oil applied in the direction of the grain, with a soft, lint free cloth. 

Another effective way to restore the 'as new' look to the stainless steel parts, is use of a proprietary car interior cleaning agent such as 'Cockpit
shine'. This should be sprayed directly on to the metal and then wiped off with a clean lint free cloth.

PAINTED AREAS - These can be cleaned using a dry cloth.

SERVICING

The fire and flue should be checked on an annual basis to ensure all of the product of combustion are entering the flue and that there is no
excessive build up of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must
be carried out by a competent person, such as a CORGI registered installer.

Cleaning of the coals/pebbles may be carried out by following the instructions given in the Installation section. The Installation instructions
carry full servicing details for the use of the installer.

If debris from the flue or other foreign matter is found on the fire it may indicate a need for servicing. Do not use the fire until the source of
the debris has been found and rectified.

Air vents (where fitted) should be checked periodically to ensure they are free from obstruction.

SHORTLIST OF SPARES

PART N

NO.

ITEM

CE/FT003033/0

Pack of 10 pebbles

CE/FT003005/0

Ceramic combustion matrix 

FB/004050/0

Ceramic brick panel set (Side cheeks and rear panel)

FR/F820074

‘Lulworth’ decorative frame

TRAY001LPG

Replacement burner unit 

3

6.0

7.0

8.0

9.0

10.0

As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications
without prior notice.

DO005830/0

Summary of Contents for LULWORTH LPG

Page 1: ...S F FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e mail sales focalpointfires co uk All i instructions m must b be h handed t to...

Page 2: ...Lulworth LPG...

Page 3: ...led by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instru...

Page 4: ...iently y v ventilated s spac ce Consult a all i instruc ctions b before i installation a and u use o of t this a applianc ce This a applianc ce i is f free f from a any y a asbestos m material R Refra...

Page 5: ...lled The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one t...

Page 6: ...liance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of f...

Page 7: ...iance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional N Note The frame of the fire any back panel...

Page 8: ...nugly around the out side of the supply pipe and sleeving Note D DO NOT install or use the appliance without this seal in place If the hole is inadvertently opened reseal with an intact grommet Failur...

Page 9: ...h fireplace openings Any sleeving should be sealed to the pipe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABL...

Page 10: ...ough the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately...

Page 11: ...cating doors open Finally repeat with all doors open BRIEFING T THE C CUSTOMER All instructions must be handed to the user for safekeeping Show the customer how to light and control the fire After com...

Page 12: ...e the tubing nut from the valve end of the pilot pipe and blow through to dis lodge any debris Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot...

Page 13: ...f for a a t time a and t then c cuts o off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pil...

Page 14: ...he elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See rele...

Page 15: ...in force OPERATING I INSTRUCTIONS The pilot is visible through the left hand side of the matrix Rotate the coals pebbles for good viewing Push in and turn the control knob to the SPARK position and h...

Page 16: ...s ensure that the fire is OFF and completely cold Debris that may form on the fuelbed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This...

Reviews: