![Focal Point LULWORTH LPG Installation And User Instructions Manual Download Page 15](http://html1.mh-extra.com/html/focal-point/lulworth-lpg/lulworth-lpg_installation-and-user-instructions-manual_2314020015.webp)
FIREFRONT
This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate airflow under the fuelbed for the correct
functioning of this appliance.
Compliance with safety standards cannot be guaranteed if another style of front is used.
CLEARANCES TTO C
COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.
A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the frame of the appliance, providing the forward
projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl and embossed paper) positioned
too close to the appliance may discolour or scorch.
VENTILATION
No ppurpose pprovided vventilation iis nnormally rrequired ffor tthis aappliance. The requirements of other appliances operating in the same space
or room, and the results of a spillage test must be taken into consideration when assessing ventilation requirements, this will have been car-
ried out by your CORGI registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force.
OPERATING IINSTRUCTIONS
The pilot is visible through the left hand side of the matrix. Rotate the coals/pebbles for good viewing.
Push in and turn the control knob to the SPARK position, and hold there for a few seconds.
Continue turning anti-clockwise through the spark click to the PILOT light position, ensuring the pilot
has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for approximately ten seconds. Now
release the knob and the pilot should stay alight. If the pilot is extinguished during use, wait three min-
utes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise to
the high position. The main burner should light after a few seconds. To decrease the setting to LOW,
turn the control knob clockwise to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. To turn
the fire OFF, keep the knob pressed in, return to the off position and release.
FUEL BED LAYOUT -
The fire is supplied with 10 ceramic pebbles. Fit the tapered brick pad into the
securing brackets in the upper area of the firebox. Place the large brick panel
against the rear of the firebox
Place the ceramic combustion matrix onto the burner and the ceramic side
cheeks onto the matrix.
2
2.0
3.0
4.0
5.0
Maximum ddepth oof sshelf
M
Minimum ddistance ffrom iinside eedge oof
fire fframe tto uunderside oof sshelf
100mm (4in)
203mm (8in)
150mm (6in)
305mm (12in)
203mm (8in)
356mm (14in)
6.0
Summary of Contents for LULWORTH LPG
Page 2: ...Lulworth LPG...