USER INSTTRUCTTIONS

IMPORTANT N

NOTES

The installation of this fire MUST only be carried out by a competent person (such as a CORGI registered fitter)
in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards, Codes
of Practice, the Building Regulations and the manufacturers’ instructions.

Failure to comply with the above recommendations could lead to prosecution and invalidate the appliance
warranty.

Please ensure you are handed all of the manufacturers documents on completion of the installation. This will
include these instructions.

Always keep a note of the installer’s name and address, the original purchase receipt and the date of installation
for future reference.

The fire and flue should be serviced regularly to ensure continued safe operation. See the servicing section for
further details. Frequency of service will depend on use, but MUST be carried out at least once annually.

Parts of this appliance become naturally hot during use. It is recommended that a suitable fire guard conforming
to BS 8423 : 2002 is used, especially where young children, the elderly, or infirm are concerned.

Combustible items, such as flooring and furniture, and soft wall coverings (such as blown vinyl or embossed
paper) may discolour if fitted too close to the fire. See relevant section for further details on clearances to
combustibles. No combustible material or flooring should protrude onto the hearth.

DO NOT burn any foreign material on this fire, the coals/pebbles must be of the correct type and laid out in
accordance with the relevant section of these instructions. Failure to do so could create a hazard or lead to soot-
ing.

Before the appliance is installed, the chimney should be swept. All flues should be checked by the installer to
ensure there are no defects or obstructions that may prevent the flow of combustion products.

This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions
occur. It is NOT a substitute for an independently mounted Carbon Monoxide detector.

The fire is only suitable for use with the gas type for which it is supplied.

1

Secction

1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0

10.0

Contentss

Important Notes
Firefront
Clearances to Combustibles
Ventilation
Operating Instructions
Fuel Bed Layout 
Flue Spillage Monitoring System
Cleaning
Servicing
Spares

Pagge N

No.

1
2
2
2
2
2
3
3
3
3

1.0

Summary of Contents for LULWORTH LPG

Page 1: ...S F FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e mail sales focalpointfires co uk All i instructions m must b be h handed t to...

Page 2: ...Lulworth LPG...

Page 3: ...led by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instru...

Page 4: ...iently y v ventilated s spac ce Consult a all i instruc ctions b before i installation a and u use o of t this a applianc ce This a applianc ce i is f free f from a any y a asbestos m material R Refra...

Page 5: ...lled The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one t...

Page 6: ...liance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of f...

Page 7: ...iance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional N Note The frame of the fire any back panel...

Page 8: ...nugly around the out side of the supply pipe and sleeving Note D DO NOT install or use the appliance without this seal in place If the hole is inadvertently opened reseal with an intact grommet Failur...

Page 9: ...h fireplace openings Any sleeving should be sealed to the pipe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABL...

Page 10: ...ough the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately...

Page 11: ...cating doors open Finally repeat with all doors open BRIEFING T THE C CUSTOMER All instructions must be handed to the user for safekeeping Show the customer how to light and control the fire After com...

Page 12: ...e the tubing nut from the valve end of the pilot pipe and blow through to dis lodge any debris Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot...

Page 13: ...f for a a t time a and t then c cuts o off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pil...

Page 14: ...he elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See rele...

Page 15: ...in force OPERATING I INSTRUCTIONS The pilot is visible through the left hand side of the matrix Rotate the coals pebbles for good viewing Push in and turn the control knob to the SPARK position and h...

Page 16: ...s ensure that the fire is OFF and completely cold Debris that may form on the fuelbed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This...

Reviews: