Over Voltage
:
Set the threshold voltage, and alarm OVP when the output
voltage exceeds the set voltage;
2.
Over Current
:
Set the threshold current, and alarm OCP when the output
current exceeds the set current;
3.
Over Power
:
Set the threshold power, and alarm OPP when the output power
exceeds the set power;
4.
Over Temp
:
Set the threshold temperature, and alarm OTP when the device
temperature exceeds the set temperature
5.
Timeout
:
Set the threshold time, when the output time exceeds the set time,
it will alarm OHP;
3.3 Intelligent temperature control system
When the product temperature is greater than 40
°
C or the output current is
greater than 2A, the fan automatically starts, and the fan automatically shuts off
when the conditions are not met.
3.4 PD Interface Description
The PD interface compatibility of this device is not very comprehensive,It is not
guaranteed to be compatible with all PD chargers,Fix the PD gear of 20V voltage.
If the charger does not support the 20V gear,Will outputthe voltage of the first
gear,Maximum load is 80W (due to the influence of PD charger and CC line, it may
be lower than 80W,Most CC lines on the market support up to 3A,Need to support
the CC line of the Emarker chip to be larger than 3A)