3.4.4 Power Amplifier Working Status
Status: Working—Power Amplifier is working normally
Booting--Power Amplifier is booting
Blocked--Power Amplifier is on protecting status; Because
of the self-protection, it would be rebooted and
turns on the RF in 10 seconds when extremely
case occurs. If the reboot failed 3 times
consecutively, then the power amplifier would
turn off the RF permanently until manually
disconnect the amplifier’s power and then
reconnect (cold reboot).
Absent-- Power Amplifier can not communicate with CCU.
Forward Power: Forward Power of the module
Reflect Power: Reflect Power of the module
Temperature: temperature of the module
Voltage: Amplifier’s power supply voltage, 48V/32V
Current
:
Each power amplifier unit has four amplifier modules;
this column is used to display the current of these four
amplifier modules.