background image

11

Operating Instructions - PREMAxx Diesel Pump

 

GB

1

Suction filter with metal screen

12 Easy-turn swivel joint-DN 19

2

Hose for diesel, DN 19

13 Nut G1“

3

2-ear hose clamp

14 Lock

4

Hose for diesel, DN 19

15 Lever, automatic nozzle valve

5

PREMAxx diesel pump

16 Lever, standard nozzle valve

6

Automatic nozzle valve, diesel

17 On/off rocker switch

7

Nozzle valve-G 1“ female-80 l/min

18 Worm drive clamp

8

Press nipple

19 Intake pipe socket

9

Bend 90°

20 Barrel screw coupling

10 Worm drive clamp

21 Discharge port

11 Intake pipe socket for PREMAxx

22 Hand lever

Connect the pump to a power source using the mains plug or the terminal clamps.

The pump is ready for commissioning.

CAUTION

Risk of injury from 24 V and 12 V batteries!

When handling the 24 V and 12 V battery (lead-acid battery), observe 
the specifications and the material data safety sheet of the battery 
manufacturer.

Carry out the following steps when connecting the pump (24/12 V) to the battery:

The switch of the pump must be in the OFF position.

Remove the protection cap from the positive battery terminal (+).

Connect the red terminal clamp to the positive battery terminal.

Remove the protection cap from the negative battery terminal (-).

Connect the black terminal clamp to the negative battery terminal.

Proceed in reverse order when disconnecting the pump from the battery:

At first, disconnect the black clamp from the negative terminal and then the red clamp from the 

positive terminal. 

Put the protection caps on the terminals again.

7.    Operation

7.1.     First and re-commissioning

Check the operativeness of the pump before use and after a failure-related or scheduled downtime.
Check the PREMAxx diesel pump and the installed accessories for completeness and damage. Replace 
any damaged components immediately. Never use a pump if damaged.

NOTE

Operate the pump by hand before putting the pump into operation 
for the first time or if the fluid column has dropped down, because the 
radial shaft seal may be destroyed by a dry run of the pump. 

Preparing the pump for operation (see fig. 6-1):

Hold the nozzle valve (6 or 7) into a container.

Push the lever (15 or 16) and keep it pushed or fix it by the lock (14)  (if equipped with automatic nozzle 
valve). Hold the nozzle valve into the container to be filled.

Summary of Contents for 23 710

Page 1: ...OPERATING INSTRUCTIONS AND SAFETY NOTES PREMAxx Diesel Pump 230 V 24 V DC 12 V DC 87 987 932 A804 GB...

Page 2: ...e duplicated or distributed neither in full or in part utilized for the purpose of competition or passed on made availabe to third parties FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbest...

Page 3: ...oil________________________________________________7 3 Transport and temporary storage ________________________________________________________8 4 Design and functional description __________________...

Page 4: ...rules legal provisions as well as all other binding rules regarding occupational safety accident prevention and environmental protection Wear appropriate protective clothing in accordance with the wor...

Page 5: ...The dash denotes lists a The arrow identifies cross references If cross references to other chapters are required within the text the expres sion is shortened for reasons of clarity Example a Chapter...

Page 6: ...iminate the cause in order to avoid consequential damages Observe the safety sheet for diesel and heating oil 2 3 Intended conditions of use The PREMAxx diesel pump is an electrically driven axial gea...

Page 7: ...ispensing container The pump is only allowed to be operated if it is screwed to the dispensing container and thus cannot carry out any uncontrolled movements The pump is only allowed to be operated if...

Page 8: ...commissioning or in case of a power failure To avoid environmental damage the electric PREMAxx diesel pump is equipped with a siphon protection system In case the discharge hose is damaged while the p...

Page 9: ...sing and pump PA 6 PA6 GF30 PA 6 PA6 GF30 PA 6 PA6 GF30 DimensionsofpumpLxWxH mm inch 130x130x350 5 1x5 1x13 7 Weight kg lbs 2 5 5 5 Tab 5 1 Technical data 6 Installation The Premaxx diesel pump is de...

Page 10: ...ry out any uncontrolled movements The pump is only allowed to be operated if the dispensing container to which the pump is connected stands on a firm and level surface Screw the pump firmly into the o...

Page 11: ...tion cap from the positive battery terminal Connect the red terminal clamp to the positive battery terminal Remove the protection cap from the negative battery terminal Connect the black terminal clam...

Page 12: ...be done by qualified technical personal ATTENTION Danger of contact with energized components When working on the electrical system of the pump disconnect the pump in addition from the power supply an...

Page 13: ...ance too high Filter resistance too high Nozzle valve not completely open Check the discharge hose Check the suction line it may be kinked or clogged Check the suction filter and the check valve Check...

Page 14: ...14 GB Operating Instructions PREMAxx Diesel Pump 13 Exploded view of the PREMAxx diesel pump 230V Fig 13 1 Exploded view of the PREMAxx diesel pump 230 V...

Page 15: ...Lever PREMAxx 18 4 Screws 4x20 19 2 Chipboard screw 4 5x70 40 20 2 Grooved taper pin DIN 1471 21 1 Ball stainless steel 22 1 Tapping screw 3 9x9 5 23 1 O ring NBR 70 35 x2 24 4 Chipboard screw 3x16 2...

Page 16: ...16 GB Operating Instructions PREMAxx Diesel Pump 14 Exploded view of the PREMAxx diesel pump 24 12V Fig 14 1 Exploded view of the PREMAxx diesel pump 24 12 V...

Page 17: ...Grooved taper pin DIN 1471 Grooved taper pin DIN 1471 20 1 Ball stainless steel Ball stainless steel 21 1 Tapping screw 3 9x9 5 Tapping screw 3 9x9 5 22 1 O ring NBR 70 35x2 O ring NBR 70 35x2 23 4 Ch...

Page 18: ...0 12 V 0 18 kW Function Pumping of diesel fuel and heating oil Complies with all relevant provisions of the following directives EC Directives 2006 42 EG Machinery Directive 2011 65 EC EU Directive Ro...

Page 19: ...19 Operating Instructions PREMAxx Diesel Pump GB...

Page 20: ...FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestra e 6 6330 Cham Schweiz Tel 41 41 712 05 37 Fax 41 41 720 26 21 info fmtag com www fmtag com...

Reviews: