background image

3

Operating Instructions - PREMAxx Diesel Pump

 

GB

Table of Contents

1. 

Introduction  ________________________________________________________________________4

1.1. 

Preface   ____________________________________________________________________________4

1.2. 

Obligations of the personnel  __________________________________________________________4

1.3. 

Symbols in this manual  _______________________________________________________________4

1.3.1. 

Structure of the warning notes  _________________________________________________________4

1.3.2. 

Hazard warning symbols  ______________________________________________________________5

1.3.3. 

General symbols  ____________________________________________________________________5

2. 

Safety notes ________________________________________________________________________5

2.1. 

Authorized personnel  ________________________________________________________________6

2.2. 

Notes for maintenance, cleaning and repair  ______________________________________________6

2.3. 

Intended conditions of use  ____________________________________________________________6

2.4. 

Risks when handling the PREMAxx diesel pump ___________________________________________7

2.5. 

Risks when handling diesel and heating oil _______________________________________________7

3. 

Transport and temporary storage _ ______________________________________________________8

4. 

Design and functional description  ______________________________________________________8

4.1. 

Area of application  __________________________________________________________________8

5. 

Technical data  ______________________________________________________________________8

6. 

Installation _________________________________________________________________________9

7. 

Operation  _________________________________________________________________________11

7.1. 

First and re-commissioning  ___________________________________________________________11

8. 

Preventive maintenance  _____________________________________________________________12

9. 

Maintenance  ______________________________________________________________________12

10. 

Troubleshooting  ___________________________________________________________________13

11. 

Repair/Service  _____________________________________________________________________13

12. 

Disposal ___________________________________________________________________________13

13. 

Exploded view of the PREMAxx diesel pump 230 V ________________________________________14

14. 

Exploded view of the PREMAxx diesel pump 24 /12 V  ______________________________________16

15. 

EC Declaration of Conformity  _________________________________________________________18

Summary of Contents for 23 710

Page 1: ...OPERATING INSTRUCTIONS AND SAFETY NOTES PREMAxx Diesel Pump 230 V 24 V DC 12 V DC 87 987 932 A804 GB...

Page 2: ...e duplicated or distributed neither in full or in part utilized for the purpose of competition or passed on made availabe to third parties FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbest...

Page 3: ...oil________________________________________________7 3 Transport and temporary storage ________________________________________________________8 4 Design and functional description __________________...

Page 4: ...rules legal provisions as well as all other binding rules regarding occupational safety accident prevention and environmental protection Wear appropriate protective clothing in accordance with the wor...

Page 5: ...The dash denotes lists a The arrow identifies cross references If cross references to other chapters are required within the text the expres sion is shortened for reasons of clarity Example a Chapter...

Page 6: ...iminate the cause in order to avoid consequential damages Observe the safety sheet for diesel and heating oil 2 3 Intended conditions of use The PREMAxx diesel pump is an electrically driven axial gea...

Page 7: ...ispensing container The pump is only allowed to be operated if it is screwed to the dispensing container and thus cannot carry out any uncontrolled movements The pump is only allowed to be operated if...

Page 8: ...commissioning or in case of a power failure To avoid environmental damage the electric PREMAxx diesel pump is equipped with a siphon protection system In case the discharge hose is damaged while the p...

Page 9: ...sing and pump PA 6 PA6 GF30 PA 6 PA6 GF30 PA 6 PA6 GF30 DimensionsofpumpLxWxH mm inch 130x130x350 5 1x5 1x13 7 Weight kg lbs 2 5 5 5 Tab 5 1 Technical data 6 Installation The Premaxx diesel pump is de...

Page 10: ...ry out any uncontrolled movements The pump is only allowed to be operated if the dispensing container to which the pump is connected stands on a firm and level surface Screw the pump firmly into the o...

Page 11: ...tion cap from the positive battery terminal Connect the red terminal clamp to the positive battery terminal Remove the protection cap from the negative battery terminal Connect the black terminal clam...

Page 12: ...be done by qualified technical personal ATTENTION Danger of contact with energized components When working on the electrical system of the pump disconnect the pump in addition from the power supply an...

Page 13: ...ance too high Filter resistance too high Nozzle valve not completely open Check the discharge hose Check the suction line it may be kinked or clogged Check the suction filter and the check valve Check...

Page 14: ...14 GB Operating Instructions PREMAxx Diesel Pump 13 Exploded view of the PREMAxx diesel pump 230V Fig 13 1 Exploded view of the PREMAxx diesel pump 230 V...

Page 15: ...Lever PREMAxx 18 4 Screws 4x20 19 2 Chipboard screw 4 5x70 40 20 2 Grooved taper pin DIN 1471 21 1 Ball stainless steel 22 1 Tapping screw 3 9x9 5 23 1 O ring NBR 70 35 x2 24 4 Chipboard screw 3x16 2...

Page 16: ...16 GB Operating Instructions PREMAxx Diesel Pump 14 Exploded view of the PREMAxx diesel pump 24 12V Fig 14 1 Exploded view of the PREMAxx diesel pump 24 12 V...

Page 17: ...Grooved taper pin DIN 1471 Grooved taper pin DIN 1471 20 1 Ball stainless steel Ball stainless steel 21 1 Tapping screw 3 9x9 5 Tapping screw 3 9x9 5 22 1 O ring NBR 70 35x2 O ring NBR 70 35x2 23 4 Ch...

Page 18: ...0 12 V 0 18 kW Function Pumping of diesel fuel and heating oil Complies with all relevant provisions of the following directives EC Directives 2006 42 EG Machinery Directive 2011 65 EC EU Directive Ro...

Page 19: ...19 Operating Instructions PREMAxx Diesel Pump GB...

Page 20: ...FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestra e 6 6330 Cham Schweiz Tel 41 41 712 05 37 Fax 41 41 720 26 21 info fmtag com www fmtag com...