RTM X42.Modbus Installation Manual and Operating Instructions
09.12.2019
17
Figure 11: Application of a defined weight force to the force sensor
RTM_X42_Modbus_BA_Manual.ai
To adjust the gain, load the measuring roller with a cable with a defined weight
attached to its end. The cable must correspond to the real material course in the
machine (wrap angle, distances between the rollers, etc.). The displayed/determined
digit value must now be assigned in the PLC to the weight force corresponding to the
calibration weight.
For the calibration of the force sensor for the core observe the operating manual of the
measuring amplifier connected to this force sensor.
5.3
Charger
Figure 12: Charger with battery
RTM_Ladegerät_Akku_10Ah_01.png
-
Connect battery to charger
-
The state of charge LED lights up red if the battery is discharged
-
The safety circuit protects the batteries from overcharging.
-
Charging is finished as soon as the battery pack reached its maximum charge
capacity. The charging process takes 3-4 hours.
-
The state of charge LED lights up green if the battery is charged
-
The battery must be connected in the battery compartment of the EMGZ482T prior
to start-up.
-
If a battery is not needed for the moment, it may remain in the charger
Flying parts
If the battery is not secured correctly, it can be ejected in the case of
rotating machines.
Secure the battery using the knurled screws. Tighten the knurled screws
sufficiently.