Operating Manual EMGZ470A/472A
17
Status byte (Status)
The status byte indicates the status of the measuring amplifier.
Slave
→
Master
Status
HIW
Bit #
7......0
Value Meaning
Remarks
00h
Ok
Acquiring of measuring value ok
02h
Overflow
The allowed measuring range is exceeded
04h
Error
An error appeared during acquiring of the measuring
value
06h
Overload
The sensor power source is overload
09h
Read Device Type
EMGZ470: HIW = 1 resp. EMGZ472: HIW = 2
21h
User Offset read
HIW = User Offset read
23h
User Offset written HIW = User-Offset written
25h
User Offset found
HIW = User Offset found
29h
User Gain read
HIW = User Gain read
2Bh
User Gain written
HIW = User Gain written
2Dh User
Gain
calibrated
HIW = User Gain calculated
F9h
Firmware Version
HIW = main version (high byte) + sub version (low
byte)
Main actual value (HIW)
The main feedback value transmits the actual measuring value.
Slave
→
Master
Status
HIW
Bit #
15......0
The main feedback value is a 16 bit word (range ±32767) which transmits the
processed measuring value of the measuring amplifier. The high byte is transmitted
before the low byte