 WARNING: Improper installation, adjustment, altera-

tion, service or maintenance can cause injury, property 

damage or loss of life. Refer to this manual for assis-

tance  or  additional  information.  Consult  a  qualified 

installer or local distributor.

saFeTy

IMPORTANT: Check local codes 

before installing this fireplace.

Models (V)PN36-A series is a wood burning fire-

place intended and approved for installation in 

either residential homes or buildings of standard 

construction. This fireplace system requires the 

utilization of FMI PRODUCTS, LLC 12" double 

wall, snap-lock flue pipe system.
Glass doors are optional with this fireplace and 

come in different styles. For more information 

see 

Glass Doors

, page 13).

Before beginning installation of this fireplace, 

read these instructions through completely.
•  This FMI PRODUCTS, LLC fireplace and its 

components are safe when installed accord-

ing to this installation manual. Unless you 

use  FMI  PRODUCTS,  LLC  components, 

which have been designed and tested for 

the fireplace system, you may cause a fire 

hazard.

•  The  FMI  PRODUCTS,  LLC  warranty  will 

be voided by and FMI PRODUCTS, LLC 

disclaims any responsibility for the following 

actions.
a. Modification of the fireplace, components, 

doors, air inlet system and damper con-

trol.

b. Use of any component part not manufac-

tured or approved by FMI PRODUCTS, 

LLC in combination with a FMI PROD-

UCTS, LLC fireplace system.

Proper installation is the most important step 

in  ensuring  safe  and  continuous  operation 

of the fireplace. Although grounding may not 

be required by code in your area, it must be 

electrically grounded in accordance with lo-

cal codes or, in the absence of local codes, 

with  the 

National  Electrical  Code,  ANSI/

NFPA 70

.

This fireplace is intended for installation in ac-

cordance with the 

National Fire Protection As-

sociation Standard for Chimneys, Fireplaces, 

Vent

and  Solid-Fuel  Burning  Fireplaces

NFPA  211

,  and  in  accordance  with  codes 

such as the 

BOCA Basic/National Code

, the 

Standard Mechanical Code

, and the 

Uniform 

Building Code

.

 WARNING: Do not install a 

fireplace insert in this firebox un-

less the manufacturer's instruc-

tions with the insert specifically 

state  this  fireplace  has  been 

tested for use with the insert.

This fireplace is not intended to be 

used as a substitute for a furnace 

to heat an entire home. Use for 

supplemental heat only.

FOR YOUR SAFETY

•  Do not store or use gasoline 

or any other flammable vapors 

or liquids in the vicinity of this 

or any other appliance.

•  Due to high temperatures, the 

appliance  should  be  located 

out  of  traffic  and  away  from 

furniture and draperies.

•  Do not place clothing or other 

flammable materials on or near 

the appliance.

•  Never  leave  children  unat-

tended when a fire is burning 

in the fireplace.

TaBle oF conTenTs

Safety .................................................................. 2

Product Dimensions ............................................ 3

Fireplace Installation............................................ 4

Venting Installation .............................................. 6

Optional Gas Line Installation............................ 12

Operation and Maintenance Guidelines ............ 13

Technical Service............................................... 14

Replacement and Accessory Parts.................... 15

Summary of Contents for (V)PN36-A

Page 1: ...ved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to deter mine the need to obtain a per...

Page 2: ...FMI PROD UCTS LLC fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Although grounding may not be required by code in your area it must be electrically grounded in accordance with lo cal codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 This fireplace is intended for installation in ac cord...

Page 3: ...lways leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted to the hazardsofhighsurfacetempera tures and to stay away to avoid burns or clothing ignition Young children should be carefully su pervised when in the same room as fireplace Figure 1 V PN36 A Dimensions Nailing Flanges 21 19 12 10 1 4 40 12 3 7 11 1 4 36 1 2 37 1 2 22 5 8 6...

Page 4: ... may be ideal for a new addition on an existing finished wall Minimum clearance to combustibles Back and sides of fireplace 1 2 min Adjacent wall 12 min Chimney outer pipe surfaces 2 min Bottom of fireplace to floor 0 min WARNING Do not block required air spaces with insu lation or any other material Do notobstructeffectiveopeningof fireplace with any type of facing material Combustible material m...

Page 5: ...ugh flanges located on sides of the fireplace see Figure 8 Fireplace Installation Continued 1 2 MIN OVERLAP 1 2 MIN Figure 7 Ember Protectors Figure 8 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 Minimum to Combustibles Hearth Extension A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to prote...

Page 6: ...ing of the fireplace due to the nature of it s location Outside combustion air is accessed through and exterior wall or a vented crawl space CAUTION Air inlet ducts must not terminate in attic space The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination For further details on installation of outside air kit please refer to instructions included with ...

Page 7: ...imney together exception see Figure 17 page 8 WARNING The opening in the collar around the chimney at the top of the fireplace must not be obstructed Neveruseblowninsula tion to fill the chimney enclosure Figure 13 Outside Air Kit Installation Secure to Collars with Duct Tape or Screws Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Termination V...

Page 8: ...FS 10 Firestop spacers are required at each point where the chimney penetrates a floor or ceiling joist space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When penetrating a floor or ceiling at an angle use firestop spacer number 30FS 10 see Re placement and Accessory Parts page 15 When the pipe passes through a framed open ing...

Page 9: ...uter pipe of chimney with screws if screws do not penetrate inner flue pipe Figure 22 Maximum Chimney Height Storm Collar Flashing Firestop Spacer RLT 12D RLT 12D STL 12D Minimum Maximum Chimney Height The minimum height of the chimney mea sured from the base of the fireplace to the flue gas outlet end of pipe is 16 feet for a straight run 16 feet minimum for a run with 1 elbow set and 25 feet min...

Page 10: ...erproof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 24 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation Place storm collar over pipe and s...

Page 11: ...tile or other noncom bustible materials may overlap the front face provided they do not obstruct essential open ings like louvered slots or any other opening When overlapping with a noncombustible facing material use only noncombustible mortar or adhesive Installing fireplace facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to ...

Page 12: ...automatic shutoff device and must comply with the Standard for Decora tive Gas Appliances for Installation in Vented Fireplace ANSI Z21 60 ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS ANSI Z21 11 2 ARE TO BE INSTALLED IN THIS FIREPLACE Use only a 1 2 black iron pipe and appropri ate fittings 1 Remove knockout indentation on refrac tory or f...

Page 13: ... chimney cleaner Creosote will ignite if heavily heated WARNING When using a decorative vented gas log the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position Note An appropriate FMI PRODUCTS LLC hood see Replacement and Accessory Parts page 15 must be installed when using an unvented gas log set Operation and Maintenance G...

Page 14: ...calling please have your model and serial numbers of your heater ready You can also visit web site at www fmiproducts com damper Mechanism The damper control lever is located inside the fire chamber see Figure 32 Make sure lever is cool before handling Pull down to close and push up to open Damper must be open when lighting a fire Not doing so will cause smoke spillage into the room When fireplace...

Page 15: ...Double Wall Pipe support assembly 12S 12DM Also available in triple wall Outside Air Kit AK4 Vent Plaster Collar Vent Hood Connector Duct 4 x 3 Storm Collar SC2 1 Firestop Spacer FS 10 for Straight Pipe 30FS 10 for 30 Angled Run Flashing V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch Round Top Termination RLT 12D Econo Top Termination STL 12D Bi Fold Glass Doors DG368ST Brushed Brass DBP36...

Page 16: ...115607 01 Rev D 09 09 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com ...

Reviews: