www.fmiproducts.com
125568-01A
24
REMOTE READy MODELS OPERATION
Continued
Note: AUTO is only functional when using
GWMT1 or GWMS2 optional accessories.
If hand-held remote control is installed
but not being used, slide remote selector
switch to ON (It must be in this position for
burners to light. Switch will be in REMOTE
position if using hand-held remote).
11. Set flame adjustment knob to any level
between HI and LO.
12. To leave pilot lit an shut off burners only:
turn control knob clockwise
to the
PILOT position, or use remote control
manual OFF button , or set selector switch
in the OFF position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
remote selector switch is in the
OFF position when you are away
from home for long periods of
time. Heater will come on auto-
matically with selector switch in
the ON position.
Figure 35 - Pilot (Natural)
Ignitor
Electrode
Pilot Burner
6. Press in and turn control knob counter-
clockwise
to the PILOT position.
Press in control knob for five (5) seconds
(see Figure 34).
Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
7. With control knob pressed in, press and
release ignitor button on left side of log set.
This will light pilot. The pilot is attached to
the front of U-shaped burner. If needed,
keep pressing ignitor button until pilot
lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 25.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise
to the ON position. If
using a hand-held remote control acces-
sory, go to
Optional Hand-Held Remote
Operation
on page 25.
10. Wait one minute and put switch in ON
position to light burners.
AUTO
OFF
ON
Figure 34 - Control Knob, Ignitor Button
and AUTO/OFF/ON Switch
Selector Switch
Control Knob in
OFF Position
Flame
Adjustment
Knob
Ignitor