LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide
greater clearances from floor,
ceiling and joining wall.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth-
ing or other flammable objects
are less than 36" (91.5 cm)
from the front, top or sides of
the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
Figure 4 - Mounting Clearances As
Viewed From Front of Heater
INSTALLATION
Continued
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18" (45.7 cm) above
floor
• locate heater where moving
vehicle will not hit it
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning fluids,
oil or kerosene lamps, etc.) in the
air exist, may discolor walls or
cause odors.
IMPORTANT
: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See
Air for Combustion and Ventila-
tion
, page 5. If high humidity is experienced,
a dehumidifier may be used to help lower the
water vapor content in the air.
For convenience and efficiency, install heater
• where there is easy access for operation,
inspection and service
• in coldest part of room
If not included with your heater, an optional fan
kit is available from your dealer. See
Acces-
sories
, page 26. If planning to use fan, locate
heater near an electrical outlet (see page 16).
THERMOSTAT SENSING BULB
(Thermostat Models Only)
The thermostat sensing bulb is located below
the heater. Do not move this bulb during instal-
lation or operation of the heater.
36" (91.5 cm)
3" (7.7 cm)
FLOOR
CEILING
Minimum
6"
(15.3 cm)
Minimum
From
Sides Of
Heater
Right
Side
Left
Side
36"
(91.5 cm)
Minimum To
Top Surface Of
Carpeting, Tile Or
Other Combustible
Material